Model T17 Installation Guide
45
Chapter 2. Installing the Pipe Nozzles
2.4.3 Determining and Marking the Second Nozzle Location - MR2 Mid-Radius (cont.)
Note:
For convenience, refer to
below for tabulated values of the
AS
dimension for some common pipe sizes.
For any values not listed in the table, calculate your
AS
dimension with the equations above.
5.
Wrap the strip of film around the pipe with one corner edge lined up with the vertical and horizontal scribe
lines at the first nozzle location (see
below). Make sure the strip overlaps
squarely
around the pipe
and that the marked line on the film from step 4 is on the outside of the film and is visible when wrapped.
Figure 56: Wrapping the Film on the Pipe
Table 8: AS Values for Common Pipe Sizes with 0.375” Wall Thickness
Pipe OD
AS Dimension
inches
mm
inches
mm
26
650
27.658
702.51
28
700
29.753
755.70
30
750
31.847
808.94
32
800
33.942
862.13
34
N/A
36.036
915.31
36
900
38.131
968.50
38
N/A
40.225
N/A
40
1000
42.320
1074.93
42
1050
44.414
1128.12
44
1100
46.508
1181.30
46
N/A
48.603
N/A
48
1200
50.697
1287.73
52
1300
54.886
1394.10
54
N/A
56.981
N/A
56
1400
59.075
1500.53
60
1500
63.264
1606.91
64
1600
67.453
1713.28
66
N/A
69.547
N/A
Top Reference Point
Содержание T17
Страница 1: ...GE Oil Gas Flow 916 128 Rev D September 2020 Model T17 Ultrasonic Flow Transducer Installation Guide ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 62: ...Chapter 2 Installing the Pipe Nozzles 54 Model T17 Installation Guide no content intended for this page ...
Страница 64: ...Chapter 3 Installing an Isolation Valve 56 Model T17 Installation Guide no content intended for this page ...
Страница 88: ...Chapter 6 Specifications 80 Model T17 Installation Guide no content intended for this page ...
Страница 90: ...Warranty 82 Model T17 Installation Guide no content intended for this page ...
Страница 92: ......
Страница 93: ......