Chapter 2. Installing the Pipe Nozzles
30
Model T17 Installation Guide
2.3.4 Installing the First Welding Boss - MR1 Mid-Radius (cont.)
2.
Scribe the
oblique center line
on the pipe from the horizontal scribe line upward around the pipe, at the
calculated or tabulated distance from the true center line. The oblique center line should be marked on the side
of the true center line that is closer to the second nozzle location. One end of the oblique centerline should stop
at the horizontal scribe line, as shown in
below.
Figure 38: Scribing the Oblique Centerline
Table 5: X Values for Common Pipe Sizes with 0.375” Wall Thickness
Pipe OD
X Dimension
NPS (inches)
DN (mm)
inches
mm
26
650
0.502
12.76
28
700
0.501
12.72
30
750
0.499
12.68
32
800
0.498
12.65
34
N/A
0.497
12.62
36
900
0.496
12.59
38
N/A
0.495
12.57
40
1000
0.494
12.55
42
1050
0.493
12.53
44
1100
0.493
12.51
46
N/A
0.492
12.50
48
1200
0.492
12.49
52
1300
0.491
12.46
54
N/A
0.490
12.45
56
1400
0.490
12.44
60
1500
0.489
12.42
64
1600
0.488
12.41
66
N/A
0.488
12.40
True Centerline
Oblique Centerline
Oblique Centerline
Ends at Horizontal Line
x
Содержание T17
Страница 1: ...GE Oil Gas Flow 916 128 Rev D September 2020 Model T17 Ultrasonic Flow Transducer Installation Guide ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 62: ...Chapter 2 Installing the Pipe Nozzles 54 Model T17 Installation Guide no content intended for this page ...
Страница 64: ...Chapter 3 Installing an Isolation Valve 56 Model T17 Installation Guide no content intended for this page ...
Страница 88: ...Chapter 6 Specifications 80 Model T17 Installation Guide no content intended for this page ...
Страница 90: ...Warranty 82 Model T17 Installation Guide no content intended for this page ...
Страница 92: ......
Страница 93: ......