GE Smart Water PNRV18ZWH01 Скачать руководство пользователя страница 9

PRESSURE TESTING THE SYSTEM

—DO THE SANITIZING PROCEDURE BEFORE PRESSURE
TESTING—INSTALLATION CHECKLIST

1.

Open the water supply valve to the Reverse Osmosis system and

open the storage tank shutoff valve.

2. Check all connections for LEAKS.

3.

In about 4 hours, pressure will build in the Reverse Osmosis

system. 

Carefully recheck all fittings and connections for water

leaks. Correct leaks if any are found.

4.

Fill sink(s) 1/2 full of tap water and drain, checking drain

plumbing for leaks.

PURGING THE SYSTEM

1.

Wait about 4 hours for the storage tank to fill.

2.

Open the RO faucet until the tank is empty and flow stops.

3.

Close the RO faucet and repeat these steps three more times.

The system is ready to make product water for use.

WARNING: Initially, the Reverse Osmosis cartridge
contains a food grade preservative that has to be purged
from the system before first use or whenever Reverse
Osmosis cartridge is replaced. The preservative will give
product water an unpleasant taste and odor. 

INSTALLATION CHECKLIST

1.

Are all tubing connections tightened? Do they run between the

points shown? No leaks!

2.

Is the faucet base leadwire connected to the electronics box

leadwire?

3.

Is the battery holder connected to the electronics box and are

the batteries installed in the holder correctly?

4.

Did you use drain option B, C or D? Make sure the 3⁄8

drain

tubing, from the faucet to the drain point, is without loops,

dips, or low-spots.

5.

Is the 

tank

shutoff valve in the open position?

6.

Is the 

water

supply shutoff valve open?

7.

Did you sanitize and purge the system?

WHAT THE REVERSE OSMOSIS SYSTEM DOES

Reverse Osmosis removes Total Dissolved Solids (TDS) and

organic matter from water by diffusing it through a special

membrane. The membrane separates minerals and impurities

from the water and they are flushed to the drain. High quality

product water goes directly to the drinking water faucet or to the

storage tank. The system makes a good supply of drinking water

each day (see 

Product Specifications

). How much it makes depends

on the feed water supply pressure, temperature, and quality.
The system includes an electronic faucet assembly with an

integrated testing feature. When water is taken from the faucet, 

a flashing green indicator light means TDS removal is within

specified limits and that water quality is good.
The prefilter and postfilter are replaceable cartridges. The carbon

prefilter removes chlorine while also filtering sediments. The

postfilter removes any other undesirable tastes and odors before

you use the water.

THE GE ELECTRONIC MONITOR SYSTEM

Indicator lights on the faucet base show Reverse Osmosis

performance when the faucet is open to dispense water.

Flashing Green Light—

The Reverse Osmosis system is providing

high quality drinking water.

NOTE:

If the Reverse Osmosis system is connected to the

refrigerator, this light will also flash when the icemaker or

dispenser is in use.
The green light may stop flashing when the supply of Reverse

Osmosis water is nearly gone and flow from the RO water faucet

decreases. This is a normal condition.

Flashing Amber “FILT” Light—

The prefilter and postfilter cartridges

need replacing. This occurs after 6 months or 900 gallons of

product water use, whichever occurs first. Also, replace the 4 “AA”

alkaline batteries in the electronics box. Good batteries are needed

to ensure correct indicator light operation. Weak batteries may

give a false “RO” light indication. Changing the batteries resets the

6 month or 900 gallon period.

Flashing Amber “RO” Light—

The Reverse Osmosis cartridge is no

longer removing at least 75% of the Total Dissolved Solids (TDS)

from the supply water. The Reverse Osmosis cartridge, flow

control, and screen need replacing.

NOTE:

Disregard initial or short periods (a few seconds) of the

flashing “RO” light. Long periods of limited or no use can cause

the TDS levels to temporarily change.

9

Flashing amber 
“RO” light

Flashing green

“OK” light  

Flashing amber

FILTER light

Fig. 7.

Содержание Smart Water PNRV18ZWH01

Страница 1: ...a refrigerator icemaker a special icemaker connection kit is required RVKIT Do not use copper tubing for the connection between the Reverse Osmosis system and the refrigerator Be sure the water supply...

Страница 2: ...nd percent rejection all vary with changes in pressure temperature and Total Dissolved Solids b Removed maximum of 2 0 ppm by the Reverse Osmosis prefilter REGULAR MAINTENANCE IS REQUIRED Chlorine wil...

Страница 3: ...n an existing sink spray attachment hole Space is required underneath for tubing to and from the faucet and for securing the faucet in place All faucet connections and installation procedures are done...

Страница 4: ...tion use plumbing code 248 CMR of the Commonwealth of Massachusetts 1 Turn off the cold water supply and attach saddle valve as shown in Fig 2B DANGER To protect yourself from serious injury or fatal...

Страница 5: ...ne adapter to the p trap and secure it with the slip joint nut and washer as shown Route the drain line from the air gap to the drain line adapter ensuring that there are no dips loops or low spots in...

Страница 6: ...the base 5 Assemble the top faucet base and hex nut onto the faucet stud Fig 4C Tighten the nut until snug 6 Insert washer into tubing adapter Securely tighten to faucet stud 7 Take the 27 length of...

Страница 7: ...pplies Fig 2A or 2B page 4 and tighten the nut securely use Teflon Tape to prevent leaks 3 To connect the electronics box a Remove the box s back cover and fasten the battery connector to the battery...

Страница 8: ...the o ring and install the clamp retainers 7 Close the red tank shutoff valve and disconnect postfilter at the tank shutoff valve Connect the Reverse Osmosis product water tubing disconnect at electr...

Страница 9: ...the storage tank The system makes a good supply of drinking water each day see Product Specifications How much it makes depends on the feed water supply pressure temperature and quality The system in...

Страница 10: ...F ASM 26 27 28 29 24 35 34 55 39 38 56 40 45 44 43 TO FAUCET AIR GAP 46 47 48 49 50 BOTTOM LITERATURE 10 NOTE Codes in the state of Massachusetts require installation by a licensed plumber and do not...

Страница 11: ...X10006 VALVE TOP 1 1 1 1 0027 WS10X10007 VALVE CENTER 1 1 1 1 0028 WS02X10010 SCREW 10 14 X 1 3 4 4 4 4 4 0029 WS22X10015 CONNECTOR W NUT 1 4 NPT 1 1 1 1 WS22X10018 CONNECTOR 1 4 NPT X 1 4 1 1 1 1 003...

Страница 12: ...GENERAL ELECTRIC COMPANY Appliance Park Louisville KY 40225...

Отзывы: