Care and cleaning of the water heater.

Draining the Water Heater

CAUTION:

Shut off gas to the water

heater at the gas control (thermostat)
gas cock or manual shut-off valve
before draining water.

DANGER:

Before manually operating

the temperature and pressure relief
valve, make certain no one will be
exposed to the hot water released by the
valve. The water drained from the tank
may be hot enough to present a scald
hazard and should be directed to a
suitable drain to prevent injury or
damage.

In order to drain the water heater, turn off
the cold water supply. Open a hot water
faucet or lift the handle on the relief valve
to admit air to the tank. 

Attach a garden hose to the drain 
valve on the water heater and direct 
the stream of water to a drain. Open 
the valve.

!

!

DANGER:

Combustible

materials, such as clothing,
cleaning materials, or
flammable liquids, etc.,
must not be placed against
or next to the water heater.

!

Housekeeping

Visually inspect pilot burner and relight if
necessary.

To ensure sufficient ventilation and
combustion air supply, proper clearances
must be maintained. 

When installed in a closet, DO NOT
block or obstruct any of the combustion
air inlet openings located around the
perimeter of the water heater. A
minimum of 1” is required between
these combustion air inlet openings and
any obstruction.

DANGER:

Before

manually operating the
relief valve, make certain
no one will be exposed to
the danger of the hot water
released by the valve. The
water may be hot enough
to create a scald hazard.
The water should be
released into a suitable
drain to prevent injury or
property damage.

DANGER:

Hotter water

increases the potential for
Hot Water Scalds.

DANGER:

Failure to

perform the recommended
Routine Preventative
Maintenance can harm the
proper operation of this
water heater, which can
cause carbon monoxide
dangers, excessive hot
water temperatures and
other potentially hazardous
conditions

!

!

!

Routine Preventative Maintenance

Properly maintained, your water heater will
provide years of dependable trouble-free
service. 
It is recommended that a periodic inspection
of the gas control (thermostat), burner,
relief valve, internal flue-way and venting
system should be made by service personnel
qualified in gas appliance repair.
It is suggested that a routine preventative
maintenance program be established and
followed by the user. 
At least once a year, lift and release the
lever handle on the temperature pressure
relief valve, located near the top of the water
heater, to make certain the valve operates
freely. Allow several gallons to flush through
the discharge line to an open drain.

NOTICE:

If the temperature and 

pressure relief valve on the hot water
heater discharges periodically, this may
be due to thermal expansion in a closed
water system. Contact the water supplier
or your plumbing contractor on how to
correct this. DO NOT plug the relief 
valve outlet.

A water heater’s tank can act as a setling
basin for solids suspended in the water. It is
therefore not uncommon for hard water
deposits to accumulate in the bottom of the
tank. If allowed to accumulate, these solids
can cover the gas control (thermostat)
sensors, causing the sensors to operate
erratically.  

Because accumulated solids can prevent the
gas control (thermostat) sensors from
accurately reading the water temperature,
the water at the fixture can be hotter than
the gas control (thermostat) dial setting. It
is suggested that a few quarts of water be
drained from the water heater’s tank every
month to clean the tank of these deposits.

Rapid closing of faucets or solenoid valves in
automatic water using appliances can cause
a banging noise heard in a water pipe.
Strategically located risers in the water pipe
system or water hammer arresting devices
can be used to minimize the problem.

The anode rod should be removed from the
water heater’s tank annually for inspection
and replaced when more than 6” of core
wire is exposed at either end of the rod. 

Make sure the cold water supply is turned
off before removing anode rod.

This water heater incorporates a
combustion shut off device that shuts 
the operation of the water heater down 
if undesirable combustion conditions occur.
Such as the presence of flammable vapors
or blockage of the combustion air inlet
openings. Please contact a Qualified 
Service Technician if this occurs.

Содержание SG Series

Страница 1: ...nition System The purpose of this manual is twofold one to provide the installer with basic directions and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual includes a parts list It is imperative that all persons who are ex...

Страница 2: ...ate is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Product Registration Card that is in the back of this manual If you do need service you can relax knowing help is only a phone call away For service call 800 431 1549 IF YOU NEED SERVICE Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instruc...

Страница 3: ...uate air supply for proper operation Be sure to inspect the vent system for proper installation at initial start up and at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding vent system inspection DANGER INSTALL THE DRAFT HOOD AND PROPERLY VENT THE WATER HEATER Gasoline as well as other flammable materials and liquids adhesives solvents p...

Страница 4: ...ure Dial DANGER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Temperature limiting valves are available see manual BU...

Страница 5: ...y federal state and or local laws rules regulations or customs LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look and smell for gas leaks Use a soapy solution to check all gas fittings and connections Bubbling at a connection indicates a leak that mu...

Страница 6: ... a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters mu...

Страница 7: ... not allow the water heater to ignite until examined by a Qualified Service Technician The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc If local codes require the use of a stand kit to raise the water heater 18 above the floor please contact the store where the water heater was purchased or any water heater distributor These ...

Страница 8: ...s directly or through vertical ducts there must be two openings located as specified above and each must have a minimum net free area of not less than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal ducts are used to communicate with the outdoors each opening must have a minimum net free area of not less than one square inch per 2000 Btu...

Страница 9: ...ank is designed with an air cushion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor water supplier or plumbing inspector for additional information regarding this subject Combustion Ai...

Страница 10: ...alve and discharge line The end of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater Make certain that drain valve is closed then open the shut off valve in the cold water supply line Open each hot water faucet slowly to allow the air to...

Страница 11: ...s than 3 8 psi 10 5 w c for natural gas or 1 2 psi 14 w c for LP gas Gas Supply The branch gas supply line to the water heater should be clean 1 2 black steel pipe or other approved gas piping material A ground joint union or ANSI design certified semi rigid or flexible gas appliance connector should be installed in the gas line close to the water heater The National Fuel Gas Code NFGC mandates a ...

Страница 12: ... Blankets Insulation blankets available to the general public for external use on gas water heaters are not necessary The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation bl...

Страница 13: ...t the venting system complies with the guidelines found in the Use and Care Manual and National Fuel Gas Code DO contact a Qualified service technician if the pilot or main burner will not stay lit The burner chamber is designed to be sealed utilizing a gasket and tamper resistant screws DON T DON T block or restrict Combustion Air Inlet Openings located around the lower portion of the water heate...

Страница 14: ...ent room to service heater Combustible materials such as clothing cleaning materials rags etc clear of the base of the heater Clearances from combustion air inlet openings observed see page 7 Gas Supply Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas leak Gas Company ...

Страница 15: ...ic chemicals such as those used for boiler treatment into this system Tee fitting for horizontal hot water supply lines Hot water supply to house From HOT outlet on water heater From HOT outlet on water heater Hot water supply to heating unit Hot water supply to house Hot water supply to heating unit R E L I E F V A L V E C O L D H O T C O L D H O T Typical Piping Diagram for Combination Potable S...

Страница 16: ...r heater be sure to read and follow the instructions on the label pictured below and all other labels on the water heater as well as the warnings printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage personal injury or death Should you have any problems reading or following the instructions in this manual STOP and get help from a qu...

Страница 17: ...ops to accumulate near water heater Do Not store or use gasoline or other flammable vapors and liquids such as adhesives or paint thinner in vicinity of this or any other appliance If such flammables must be used open doors and windows for ventilation and all gas burning appliances in the vicinity should be shut off including their pilot burners to avoid vapors lighting NOTICE Flammable vapors can...

Страница 18: ...aken The hottest temperature water will be at the top of the tank closest to the outlet pipe delivering hot water to the home Stacking can cause this top layer of water to be hotter than the water toward the bottom of the tank near the gas control thermostat Therefore always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald ...

Страница 19: ...ars of dependable trouble free service It is recommended that a periodic inspection of the gas control thermostat burner relief valve internal flue way and venting system should be made by service personnel qualified in gas appliance repair It is suggested that a routine preventative maintenance program be established and followed by the user At least once a year lift and release the lever handle ...

Страница 20: ...ng shut down period the water heater s operation and controls should be checked by qualified service personnel Make certain the water heater is completely filled again before placing it in operation NOTICE Do not remove the anode rod from the water heater s tank except for inspection and or replacement as operation with the anode rod removed will greatly shorten the life of the glass lined tank an...

Страница 21: ...ced by a clogged qualified service technician Gas Cock Knob not See the Lighting The Water Heater section of this correctly positioned manual Pilot does not stay Loose thermocouple The connection at the gas control thermostat should lit when the RED be tightened by a qualified service technician button is released Thermocouple defective The thermocouple should be replaced by a qualified service te...

Страница 22: ...cessary relight using the instructions in the Lighting The Water Heater section of this manual The gas control thermostat See the Water Temperature Setting of The Water may be set too low Heater section of this manual Leaking or open hot water Make sure all faucets are closed faucets Combustion Shutoff System Contact a qualified service technician tripped Water is too hot The gas control thermosta...

Страница 23: ...Safety Instructions Installation Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Customer Service 23 Notes ...

Страница 24: ...Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions 24 Notes ...

Страница 25: ...y Tube The kit provides extra speed clips and tamper resistant screws Not supplied with all models Burner Assembly Kit Heat Trap Nipple Heat Trap Nipple Replacement parts For 30 40 and 50 gallon models using natural or LP gas Instructions For Placing a Parts Order To place orders using a Visa MasterCard call 800 431 1549 All parts orders should include The model and serial number of the water heat...

Страница 26: ... Manufacturer s National Service Department at the following address 2600 Gunter Park Drive Montgomery AL 36109 1413 When contacting the manufacturer the following information will be requested Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater Address where the water heater is located and physical location Name and address of installer an...

Страница 27: ...Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here 27 ...

Страница 28: ...Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing the registration below store this document in a safe place It contains information you will need should you require service Read your Use and Care Manual carefully It will help you operate your new appliance ...

Отзывы: