22
31-7000091 Rev. 3
Installation Instructions
Locate the two “knockout” plates, on the rear
oven panel, near the top of the oven.
Using tin snips, carefully cut the web area from
the two holes side-by-side (that secure the
knockouts to the oven). Cut all four webs on both
rear knockouts; this will allow the ventilation fan
airflow to exhaust out the rear of the oven.
CAUTION
Be sure to trim the sharp
edges from the openings after removing the
knockout plates.
Place the blower unit back into the opening.
AFTER: Fan
Blade Openings
Facing Back
Replace the blower plate in the same
position as before and replace the screws for
the blower plate and blower motor. Attach the
cover on the blower plate with screw.
CAUTION
Do not pull or stretch the
blower unit wiring. Make sure the wires
are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
6
7
Snip all 4 webs
on each knockout
panel and remove
the metal
knockouts for rear
airflow.
Oven Rear Panel
5
Blower Plate
Back of Oven
Blower
Plate
Screws
Blower Motor Screws
Cover Plate
MOUNT THE OVEN
C5.
FOR EASIER INSTALLATION AND PERSONAL
SAFETY, WE RECOMMEND THAT
TWO PEOPLE
INSTALL THIS OVEN.
IMPORTANT: Do not grip or use handle
during installation.
NOTE:
If your cabinet is metal, use the nylon
grommet around the power cord hole to prevent
cutting of the cord.
NOTE:
We recommend using filler blocks if the
cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are not
used, case damage may occur from over
tightening screws.
NOTE:
When mounting the microwave, thread
power cord through hole in bottom of top cabinet.
Keep it tight throughout Steps 1–3. Do not pinch
cord or lift microwave oven by pulling cord.
Lift microwave, tilt it forward, and hook slots
at back bottom edge onto four lower tabs of
mounting plate.
Rotate front of microwave oven up against
cabinet bottom.
1
2
Power Cord