TROUBLESHOOTING TIPS

Problem

Solution

No Display

Check for 24 VAC; display is blank 
when 24 VAC is not present

System fan does not 
come on properly

Verify that wiring is correct.

All thermostat but-
tons are inoperative

Verify that 24 VAC is present; unit 
will not operate when 24 VAC is not 
present.

Thermostat turns on 
and off too fre-
quently

Adjust temperature differential 

VHH&RQ¿JXUDWLRQ0RGH6HWWLQJ

Temperature Differential, Stage 1 and 
Stage 2 section).

Fan runs continu-
ously

Check 

Fan Auto/On

 switch.  If set to 

ON 

position, fan will run.

Room temperature 
is not correct

Verify that wall hole is plugged with 

SXWW\RULQVXODWLRQWRSUHYHQWDLUÀRZ

from the wall cavity.  Adjust Tempera-

WXUH2IIVHWVHH&RQ¿JXUDWLRQ0RGH

- Room temperature offset section).

Compressor doesn’t 
run or turn off im-
mediately when 
changing function 
or setting

There is a 3 minute time delay and 
a 3 minute minimum run time for the 
compressor when it turns on/off.

Fan doesn’t run or 
turn off immedi-
ately when changing 
function or setting

This is normal.  On some models, the 
fan may have a minimum run time/off 
time delay.

Problem not listed 
above

Press the 

Reset 

button once to reset 

the thermostat and restore all factory 
settings.

Содержание RAK148F2

Страница 1: ...STALLATION 4 7 CONFIGURATION MODE 8 9 OPERATING FUNCTIONS 10 TESTING THERMOSTAT 11 12 TROUBLESHOOTING 13 WARRANTY 16 THERMOSTAT Digital Non Programmable OWNER S MANUAL INSTALLATION INSTRUCTIONS RAK148F2 RAK164F2 LIA319 9 7757 05 16 GEA ...

Страница 2: ...tat only as described in this manual Electrical rating 24 VAC 18 30 VAC 1 amp maximum per terminal 4 amp maximum total load Operating temperature range 40 F 99 F 4 C 37 C Temperature set range 60 F 85 F 15 C 29 C Accuracy 1 F 0 5 C System configurations RAK148F2 2 stage heat heat pump resistance heat 1 stage cool 2 speed fan RAK164F2 1 stage heat resistance heat 1 stage cool 2 speed fan Terminatio...

Страница 3: ...igh Display Up Down Buttons Function Switch Fan Auto On Switch B GH GL Y W C R COOL OFF HEAT RESET RIGHT LEFT AUTO ON HIGH LOW Display Up Down Buttons Wiring Channel Mounting Hole Function Switch Fan Auto On Switch Mounting Hole Configuration Buttons Fan Speed Switch Fan Speed High Low ...

Страница 4: ...ing the appropriate circuit breaker to the OFF position before removing the existing thermostat Failure to do so could result in risk of electric shock PACKAGE CONTENTS TOOLS REQUIRED Package includes Thermostat on base thermostat cover wiring labels screws and wall anchors Tools needed ULOO ZLWK Ǝ ELW KDPPHU VFUHZGULYHU and putty ...

Страница 5: ...2 Remove cover of old thermostat This should expose the wires 3 Label the existing wires with the enclosed wire labels before removing wires 4 After labeling wires remove wires from wire terminals 5 Remove existing thermostat base from wall 6 Refer to the following section for instructions on how to install this thermostat INSTALLATION INSTRUCTIONS ...

Страница 6: ...on the thermostat to Off 3 Remove the cover by inserting and twisting a coin or screwdriver in the slots on the top of the thermostat 4 Put thermostat base against the wall where you plan to mount it Make sure wires will feed through the wire opening in the base of the thermostat 5 With the base level mark the placement of the mounting holes 6 Set thermostat base and cover away from working area 7...

Страница 7: ...ing on the corresponding terminal contact See the Wiring Diagrams section of this manual NOTICE Make sure exposed portion of wires does not touch other wires 13 Gently tug wire to be sure of proper connection Double check that each wire is connected to the proper terminal 14 Replace cover on thermostat by snapping it in place 15 Plug the unit in or turn on power to the system at the main service p...

Страница 8: ...8 WIRING DIAGRAMS Table 1 Terminals for six wires 1 stage heat 1 stage cool system RAK164F2 only GL GH Y W C R LO W HIG H ...

Страница 9: ...9 Table 2 Terminals for seven wires 2 stage heat 1 stage cool system RAK148F2 only WIRING DIAGRAMS B GH Y W C R GL LO W HIG H ...

Страница 10: ...button to change settings within each screen Press the RIGHT button to advance to the next screen Press the LEFT button to return to the previous screen NOTE To exit configuration mode at any time slide the Function switch to Heat or Cool Configuration Mode Settings The setup screens for Configuration Mode are as follows 1 Temperature Scale F or C Choose Fahrenheit or Celsius Press the or button t...

Страница 11: ...ess the or button to select Press the RIGHT button to advance to the next screen Note Default factory setting is 60 F 15 C 5 Maximum Heat Setpoint 65 70 72 74 76 78 80 85 F 18 21 22 23 24 26 27 29 C Adjust to control the maximum Heat set temperature allowed Press the or button to select Press the RIGHT button to advance to the next screen Note Default factory setting is 85 F 29 C 6 Room temperatur...

Страница 12: ...vices manual fan can operate Off is also used to access Configuration mode Cool In this mode the thermostat controls the cooling system Press the or button to set the desired temperature Heat In this mode the thermostat controls the heating system Press the or button to set the desired temperature ...

Страница 13: ...peed 3 Slide Fan Speed switch to Low 4 Indoor fan slows to low speed 5 Slide Fan Auto On switch to Auto position 6 Indoor fan turns off Cool Test 1 Slide Function switch to Cool position Cool mode screen is displayed 2 Adjust set temperature so it is 5 degrees below room temperature 3 Air conditioning should come on within a few seconds 4 Adjust the set temperature so it is 2 degrees above the roo...

Страница 14: ...s above room temperature 3 Heat should come on within a few seconds 4 Adjust the set temperature so it is 2 degrees below the room temperature and the heat should turn off Note There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on off On some models the fan may also have a minimum run time off time delay ...

Страница 15: ...switch If set to ON position fan will run Room temperature is not correct Verify that wall hole is plugged with SXWW RU LQVXODWLRQ WR SUHYHQW DLUÀRZ from the wall cavity Adjust Tempera WXUH 2IIVHW VHH RQ JXUDWLRQ 0RGH Room temperature offset section Compressor doesn t run or turn off im mediately when changing function or setting There is a 3 minute time delay and a 3 minute minimum run time for t...

Страница 16: ...supply voltage accident fire floods or acts of God Ŷ Incidental or consequential damage caused by possible defects with this thermostat Staple your receipt here Proof of the original purchase date is needed to validate the warranty This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within the USA and Canada In Alaska the warranty excludes th...