background image

6

TO INSTALL THERMOSTAT 

(cont.)

13.

Replace cover on thermostat by snapping it in place.

14.

Turn on power to the system at the main service
panel.

15.

Test thermostat operation as described in “Testing the
Thermostat”.

INSTALLATION INSTRUCTIONS

Wiring diagrams.

Table 1: Terminals for five wires heat/cool system
(RAK164D1 only)

R       C       W       Y       G

24 V

AC HOT

24 V

AC COMMON

AUXILIAR

Y HEA

T—ELECTRIC

COM

PRESSOR

INDOOR F

A

N

Note: 

Connect G terminal of thermostat to Zoneline Gl

terminal for low fan speed or terminal Gh for high fan speed.
Only one can be selected.

Содержание RAK148D1

Страница 1: ... Introduction Overview 3 Operating Functions 11 12 Product Registration 13 14 Specifications 2 Starting the Thermostat 10 TerminalDesignator Descriptions 10 Testing the Thermostat 10 11 Troubleshooting Tips 12 Warranty 16 RAK148D1 RAK164D1 Owner s Manual Installation Instructions LIA220 49 7543 04 06 JR Thermostats ...

Страница 2: ...r A C system and cause personal injuries Use this thermostat only as described in this manual Electrical rating 24 VAC 18 30 VAC 1 amp maximum per terminal 4 amp maximum total load Operating temperature range 40 F 99 F 4 C 37 C Temperature set range 60 F 85 F 15 C 29 C Accuracy 1 F 0 5 C System configurations 2 stage heat RAK148D1 heat pump resistance heat 1 stage heat RAK164D1 resistance heat 1 s...

Страница 3: ...DIAGRAM R12 INTRODUCTION OVERVIEW 3 Reset Switch SW5 SW6 Display Function Switch Fan Auto On Switch Toggle Up Down Switches THERMOSTAT CONTROL Display Toggle Up Down Buttons Function Switch Fan Auto On Switch ...

Страница 4: ...eforeremovingtheexistingthermostat TO REMOVE EXISTING THERMOSTAT 1 Turnoffpowertoheatingandcoolingsystembyremoving the fuse or switching off the appropriate circuit breaker 2 Removecoverofoldthermostat Thisshouldexposethewires 3 Label the existing wires with the enclosed wire labels before removing wires 4 After labeling wires remove wires from wire terminals 5 Remove existing thermostat base from...

Страница 5: ...holes in the locations you have marked for mounting 7 Use a hammer to tap supplied anchors in mounting holes 8 Align thermostat base with mounting holes and feed the control wires through the wire opening 9 Use supplied screws to mount thermostat base to wall 10 Insert stripped labeled wires in matching wire terminals See Wiring Diagrams section of this manual CAUTION Make sure exposed portion of ...

Страница 6: ...ion as described in Testing the Thermostat INSTALLATION INSTRUCTIONS Wiring diagrams Table 1 Terminals for five wires heat cool system RAK164D1 only R C W Y G 24 VAC HOT 24 VAC COMMON AUXILIARY HEAT ELECTRIC COMPRESSOR INDOOR FAN Note Connect G terminal of thermostat to Zoneline Gl terminal for low fan speed or terminal Gh for high fan speed Only one can be selected ...

Страница 7: ...148D1 only R C W Y G B 24 VAC HOT 24 VAC COMMON AUXILIARY HEAT ELECTRIC COMPRESSOR INDOOR FAN REVERSING VALVE HEAT ACTIVE Note Connect G terminal of thermostat to Zoneline Gl terminal for low fan speed or terminal Gh for high fan speed Only one can be selected ...

Страница 8: ... button to change settings within each screen 5 Press the SW6 button to advance to the next screen Note The SW5 button will return you to the previous screen 6 To exit configuration mode slide the Function switch to Heat or Cool Configuration Mode Settings The setup screens for Configuration Mode are as follows 1 Temperature Scale F or C Choose Fahrenheit or Celsius Press the or button to select P...

Страница 9: ...emperature allowed Press the or button to select Press the SW6 button to advance to the next screen 5 Maximum Heat Setpoint 65 70 72 74 76 78 80 85 F 18 21 22 23 24 26 27 29 C Adjust to control the maximum Heat set temperature allowed Press the or button to select Press the SW6 button to advance to the next screen 6 Room temperature offset 9 F to 9 F 5 C to 5 C Adjust to calibrate displayed room t...

Страница 10: ...at is installed it should be thoroughly tested CAUTION Do not use air conditioning when the outdoor temperature is below 50 degrees This can damage your air conditioning system and cause personal injuries Cool Test 1 Slide Function switch to Cool mode 2 Adjust set temperature so it is 5 degrees below room temperature 3 Air conditioning should come on within a few seconds 4 Adjust the set temperatu...

Страница 11: ...ed each time the thermostat is switched from Off or Cool modes to Heat mode Electric heaters are energized until the thermostat set point is reached Heat pump operation will resume at next call for heat Heat pump only Fan Test 1 Slide Fan Auto On switch to On position 2 Indoor fan turns on 3 Slide Fan Auto On switch to Auto position 4 Indoor fan turns off Cool Heat Off Auto On Auto On Operating fu...

Страница 12: ...Auxiliary heat not on Adjust differential for 2nd stage soon enough RAK148D1 only heating if required see Configuration mode Compressor doesn t run There is a 3 minute time delay and or turn off immediately a 3 minute minimum run time for when changing function the compressor when it turns on off or setting Fan doesn t run or turn off This is normal On some models the immediately when changing fan...

Страница 13: ...13 General Electric Company Warranty Registration Department P O Box 32150 Louisville KY 40232 2150 Please place in envelope and mail to ...

Страница 14: ...ectric Company Louisville KY 40225 ge com First Name Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Model Number Serial Number E mail Address Occasionally we may allow selected companies to send you information Check here if you do not want this information ...

Страница 15: ...Notes 15 ...

Страница 16: ...ge accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this thermostat Staple your receipt here Proof of the original purchase date is needed to validate the warranty This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within the USA and Canada In Alaska the warranty excludes the cost of ship...