background image

4

DRAIN KIT

If it is necessary to install a drain kit on this wall
case, the following kit is available:

RAD10

Internal/External Drain

1.

With an “Internal Drain”, the condensate drain
tube must be connected to an internal drain
system in the building.

2.

With an “External Drain” (which may be connected
to a field supplied drain line) condensate water can
be drained away from the unit and building.

Note:

It may be desirable or necessary to install the 
drain kit on the case prior to installing the case into
the wall.

Square drain holes

Neoprene sponge gasket

Steel mounting plate

Type “A” screws

1/2

 O.D. drain tube

Alternate
6

 long, 1/2

O.D. straight
copper tube.

Overflow relief drains

See detail

below

Overflow relief drain

Square drain holes

Neoprene sponge gasket

Steel mounting plate

Type “A” screws

Gasket

Speed nuts

Cabinet bottom

Tube

Cover plate

Type “A” screws

1/2

 

O.D.

WALL CASE WITH RAD10 DRAIN UNIT

INTERNAL DRAIN

WALL CASE WITH RAD10 DRAIN UNIT

EXTERNAL DRAIN

SCREW

Type “A”

METAL

Specifications subject to change without notice

A Quality Product of GE Appliances

ELECTRICAL REQUIREMENTS (230/208V)

Provisions should be made to have the proper
electrical outlet near the case. All wiring should be
made in accordance with local codes and
regulations. The line cord included with the chassis
(if used) will extend to a wall receptacle located
within the area shown in tabulation below.

Wall Receptacles

All wiring should be made in accordance with local
electrical codes and regulations.

See the Owner’s Manual for how to connect
electrical supply. 

Note:

Aluminum wiring in structure may pose special
problems—consult a qualified electrician.

“A”

Inside

“B”

Model

“A”

“B”

AZ Series

21

58

230V/208V 15 amp

230V/208V 20 amp

230V 30 amp

“tandem” type

“perpendicular” type

“tandem” type

ELECTRICAL REQUIREMENTS (265V)

Warning:

Connection of a 265V product to a branch circuit

MUST

be done by direct connection to be in

compliance with the National Electric Code.
Plugging a 265V unit directly into a building
mounted exposed receptacle is not permitted by
code.

See the Owner’s Manual for how to connect
electrical supply. 

Содержание RAB-71

Страница 1: ... is used If more than 6 of the case projects into the room a sub base or other support is recommended C Projection of case to outside 1 4 min D Height above finished floor or top of carpet 0 min without sub base 3 min with sub base E Left Right side of case to adjacent wall 2 min Top of case Outside wall E E Pub No 30 7795 2 04 00 JR INSTALL CASE LEVEL IN ALL DIRECTIONS Note Handle the case carefu...

Страница 2: ...l the chassis is installed If field supplied case angles are to be used and must be installed proceed as follows 1 Position the case angles around top and sides of the case at the desired location front to rear with angles facing toward rear outside Position the case angles vertically on each side of the case to provide a level installation 2 Mark the case through the holes in the case angles 3 Dr...

Страница 3: ...e the Owner s Manual for how to connect the electrical supply STEP 4 Weather proofing Weather proof gaps between the exterior and interior walls and the case with caulking or equivalent weather proofing material Stiffener Inside wall Secure case thru side or top only For installation in extra thick walls 1 If the case is being installed in a thick wall where the case is recessed more than 3 an ext...

Страница 4: ...RAIN SCREW Type A METAL Specifications subject to change without notice A Quality Product of GE Appliances ELECTRICAL REQUIREMENTS 230 208V Provisions should be made to have the proper electrical outlet near the case All wiring should be made in accordance with local codes and regulations The line cord included with the chassis if used will extend to a wall receptacle located within the area shown...

Отзывы: