14
conductor or the grounding electrode conductor metal
enclosure of the power service
• An 8ft. grounding rod driven into the ground can be
used as long as it is connected to the central building
ground by a #6 or heavier bonding wire.
Refer to the NEC sections 250 and 810 for other acceptable
grounding methods.
Double-check all your connections after installation is
complete. Ensure there are good electrical connections of your
grounding wires and coax cables. See Fig. 5d for an example of
a properly grounded antenna installation.
IF YOU ARE UNSURE HOW TO PROPERLY GROUND YOUR
ANTENNA INSTALLATION, CONTACT A PROFESSIONAL
INSTALLER IN YOUR AREA.
ANTENNA REMOVAL
Inspect the area carefully for power lines. Look for any new
power lines that may have been installed. Make sure there is no
possibility the antenna, its mounting structure or your ladder
can contact power lines. Consider what can go wrong during
the antenna removal. Repeat the steps for antenna installation
in reverse order.
(Fig. 5d)
-
Содержание Quadcore HD
Страница 31: ......