GE PVIG940 and Скачать руководство пользователя страница 16

Installation  Instructions

1 6

CEILING  INSTALLATION

  - 

Continued

11. Insert  the  other  chimney  and  keep  it  raised.  Fix  the

low  connector  to  the  connection  box.  Then  fasten  the

outlet  duct  onto  the  transition.

12. Bring  the  canopy  together  with  the  telescopic

structure,  and  fasten  them  together  using  4  screws

(M8  x  16).

Then  you  can  carry  out  the  electrical  connection

(consult Step  19

of

“WALL INST ALLATION”

instructions

on  previous  page).

13. Lower  the  chimney  and  fasten  it  on  the  sides  to  the

hood.

Ø  6  x  80

Ø  3.5  x  9.5

M8  x  16

14. Install  the  glass  vapour  catcher  with  4  screws  and

bushes,  place  the  rubber  tape  between  the  canopy

metal  edge  and  the  glass  (see  drawing ) 

Содержание PVIG940 and

Страница 1: ...aces 5 Installation Instructions 7 16 Troubleshooting Tips 18 Consumer Support Consumer Support Back Cover Product Registration 19 20 Warranty 21 Write the model and serial numbers here Model ________________ Serial ________________ You can find them on a label on the inside of the hood PVWS930 PVWS936 PVWT936 PVWG936 PVIG940 Owner s Manual and Installation Instructions www GEAppliances ca LI3FQC ...

Страница 2: ...t vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING To reduce the risk of fire or electric shock DO NOT use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn o...

Страница 3: ...Y TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideli...

Страница 4: ...ided with a storage device which counts the number of hours of operation and which regulates the lighting up of the coal filter saturation LEDS For the correct operation of this device it is important that the hood be switched off by pressing button A before unplugging it for any maintenance work A B D F C E G H I Hood Operation Turn the fan on for approximately 5 minutes before you start cooking ...

Страница 5: ...dry completely before reinstalling them To clean the hood surface For general cleaning operations rub the external part of the hood made of glass using soapy water or household cleaning products rinsing it thoroughly and drying it with a soft dry cloth to avoid marks being left by the water Stainless Steel Surfaces Do not use a steel wool pad it will scratch the surface Shake bottle well Place a s...

Страница 6: ...are cool before cleaning or servicing any part of the vent hood Unscrew the lamp diffusers Remove the blown lamp and replace it with a new 20 Watt max 12 Volt halogen lamp with a G 4 cap Follow the instructions given on the lamp box Do not touch the lamp with your bare hands Place the lamp diffuser back in place Fig 3 Replacement of lamps Models PVWS930 PVWS936 PVWT936 PVWG936 PVIG940 ...

Страница 7: ...t TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION CAUTION WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all appli cable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through th...

Страница 8: ...DIMENSIONS 1 Ft 0 3 m 1 2 5 cm 12 13 4 2 5 15 7 24 8 PVWG936 MODEL W D H PVWT936 PVWG936 PVIG940 12 13 4 2 5 15 7 24 8 PVIG940 PVWS930 93 30 36 19 3 33 3 45 7 15 75 T 36 19 3 38 6 55 5 15 75 36 19 7 33 3 47 4 17 7 17 7 31 5 41 5 39 4 27 5 PVWT936 T 5 9 10 8 D H W ...

Страница 9: ...acturer s guidelines and safety standards such as those published by NFPA and ASHRAE DUCT FITTINGS Using a smaller diameter duct size will reduce performance Actual length of straight duct plus duct fitting equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood Duct...

Страница 10: ...g Kit Kit 02282 Models PVWS930 936 PVWT936 Carbon Filter Filtrating Deflector Changes Hood from Venting to Filtrating Kit 02283 Models PVWG936 PVIG940 Carbon Filter Filtrating Deflector Rounded transition Changes Hood from Venting to Filtrating PARTS PROVIDED Hood canopy with internal blower grease filters and lights already installed Duct covers Duct Cover support bracket Transition may be alread...

Страница 11: ...ansition may be already installed Use Care and Installation Guide Hardware Packet Note the hardware packet contains several fittings material For model PVIG940 consider what is listed below ONLY Allen Wrench Rubber tape for glass vapour catcher Bushes x 4 for glass vapour catcher 6 x 20 screws x 4 for glass vapour catcher Template 6 x 80 screws x 4 washers x 4 To attach the chimney structure to th...

Страница 12: ...e and fasten the template to the wall using adhesive tape as indicate above at point 3 Ø 6 x 80 Models PVWS930 936 and PVWT936 A Centerline B Mounting Hook Location C Fastener Locations D Mounting Height Reference E Template Model PVWG936 A Centerline B Mounting Hook Location C Fastener Locations D Mounting Height Reference E Template 9 Models PVWS930 936 and PVWT936 Attach the 2 hooks with leveli...

Страница 13: ...s D Leveling Screws Model PVWG936 Ø 6 x 80 17 Install the transition at the top of the hood in case it has been removed Models PVWS930 936 and PVWT936 Ø 6 x 80 Ø 3 5 x 9 5 Model PVWG936 Ø 3 5 x 9 5 18 Connect ducting to transition Seal with duct tape Do not use duct smaller than the transition 19 Electrical connection WARNING Electrical Shock Hazard Turn off power circuit at the service panel befo...

Страница 14: ... secure junction box cover 20 Check all light bulbs to make sure they are secure in their sockets Turn power On in service panel Check lights and blower operation 21 Install filters 22 Install duct covers with 4 screws 23 Model PVWG936 Install the glass vapoure catcher with 4 screws and bushes place the rubber tape between the canopy metal edge and the glass see drawing Model PVWG936 Ø 3 5 x 9 5 D...

Страница 15: ... keep it Cut the dry wall of the ceiling and remove it Install some wooden strips of suitable length 2 x 4 between the joists to create the assembly points of the chimney flue Use the template for the dimensions and to define the space required Make sure you fasten the wooden strips safely and level Consult a professional if you are having difficulty or if this is your first installation 5 Install...

Страница 16: ...her with the telescopic structure and fasten them together using 4 screws M8 x 16 Then you can carry out the electrical connection consult Step 19 of WALL INSTALLATION instructions on previous page 13 Lower the chimney and fasten it on the sides to the hood Ø 6 x 80 Ø 3 5 x 9 5 M8 x 16 14 Install the glass vapour catcher with 4 screws and bushes place the rubber tape between the canopy metal edge ...

Страница 17: ...17 Notes www GEAppliances ca Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning ...

Страница 18: ...not need to call for service P r o b l e m P o s s i b l e Causes What To Do Fan does not operate A fuse may be blown or a Replace fuse or reset circuit breaker when the switch is on circuit breaker tripped Fan fails to circulate air Excessively soiled filters Remove the filters clean if necessary and replace or moves air slower than them If cleaning and replacing the filters does not normal corre...

Страница 19: ...ERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR RÉSIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et envoyez à ...

Страница 20: ...NO NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND RÉG TELEPHONE TÉLÉPHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHETÉ UN CONTRAT DE SERVICE POUR CET APPAREIL YES OUI NO NON IF YES SI OUI EXPIRATION Y A M D J NAME OF SELLING DEALER NOM DU MARCHAND INSTALLATIONDATE DATED INSTALLATION Y A M D J CORRESPONDENCE ENGLISH CORRESPONDANCE F...

Страница 21: ...aple your receipt here Proof of the original purchase date is needed to obtain service under the warranty Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning 21 This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within Canada If the product is located in an area where service by a Mabe Auth...

Страница 22: ...ca Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 1 800 661 1616 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualifi...

Страница 23: ......

Страница 24: ......