Page 48
XI. SPECIAL EDITION ON MAINTENANCE OF ENVIRONMENTAL PROTECTION
REFRIGERATOR
11.3.3
Sequence of extracting vacuum and
filling nitrogen
i.
Vacuum Extraction
Vacuum extraction (5 min.)
Freon filling (50 g)
Vacuum extraction (20 min)
Freon filling (presumed amount).
No reverse flow of the vacuum pump
oil. The power of vacuum pump cannot
be switched off until the operation of
the aforesaid
~
is completed
(continuous vacuum extraction
without pause).
Please operate by the following
sequence
(Compound Pressure Gauge
Specially Used for HFC-134a)
Fig. Sequence of valve operation
Each valve means the operational sequence:
- Means the closed condition of valve
- Means the opened condition of valve
CB (liquid side)
Diversified tube at the
dryer side
To the filling tube
of compressor
LB
VB
HB
A
Filling tank
Vacuum pump
L
H
ii. Preparations
a.
Fill the freon in the freon filling
tank. The required filling
50g + a
Note
:
The air in the freon
filling tank and the
connecting tube
must be
discharged.
b.
By the connection method
shown on the right side figure,
close all the valves.
c.
Connect the compressor to
the starter and the overload
protector, making it operable.
Freon tank
Filling tank
CB
CA
Содержание PTG440SAMR
Страница 53: ...Page53 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR ...
Страница 54: ...Page54 XII PART LIST AND EXPLODED VIEW PTV15SAMR PTU427SAMR PTQ440SAMR PTG440SAMR ...
Страница 61: ...Page61 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR ...
Страница 62: ...Page62 XII PART LIST AND EXPLODED VIEW PTV16SAMR PTU463SAMR PTQ470SAMR PTG470SAMR ...
Страница 70: ...Page70 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR ...
Страница 71: ...Page71 XII PART LIST AND EXPLODED VIEW PTV19SAMR PTU527SAMR PTQ530SAMR PTG530SAMR ...
Страница 78: ...Page78 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR ...
Страница 79: ...Page79 XII PART LIST AND EXPLODED VIEW PTV20SAMR PTU565SAMR PTQ570SAMR PTG570SANR ...