– 15 –
Note: When servicing the inverter, it is important
to dress the wiring to keep low-voltage DC wiring
and 120 VAC wiring separate.
To remove the inverter:
1. Unplug the unit.
2. Remove the rear access cover.
3. Remove the screw securing the water valve
and position to access the inverter.
4. Remove 1 screw (1/4 in) securing the inverter.
Slide the inverter forward to release the back
tab from the machine compartment bottom.
Note: It may be necessary to bend the process
tube in order to remove the inverter. If it is
necessary to bend the process tube, use extreme
care.
5. Turn the inverter horizontally and slide out of
the machine compartment.
To remove the inverter cover:
Use a small screwdriver to release the two small
tabs and carefully remove the inverter cover.
Compressor Lead
Wires
Compressor Lead
Wires
Signal Wire Connector
(From Main Control Board)
Inverter
Inverter
Signal Wire Connector
(From Main Control Board)
Line-In (L1)
Line-In (L1)
Tabs
Water Valve
Inverter