background image

49-2000915   Rev. 0

21

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Troubleshooting tips ...

 Before you call for service

Problem

Possible Cause

What To Do

Fan/Light does not 
operate when either 
button is pressed

A house fuse may be blown or a 
circuit breaker tripped.

Replace fuse or reset circuit breaker.

Fan does not operate 
when fan + or – buttonsor 
MEMORY/OFF button is 
pressed

The blower connector is loose 
or not plugged into its mating 
connector.

Disconnect power to the unit. Remove the filters and look 
up at the blower. If the blower connector plug is loose or 
you see the connector dangling, the installer failed to plug 
it in securely. See the Installation Instructions for the plug 
location and how to plug in the connector.

Loud or abnormal airflow 
noise

Wrong duct size used in 
installation.

7KLVKRRGUHTXLUHV´PLQLPXPGXFWLQJWRSHUIRUPRSWLPDOO\

Using smaller duct pipe will cause improper venting. GE 
Appliances service technicians cannot correct this issue if 
installed improperly.

Fan fails to circulate 
air or moves air slower 
than normal and/or fan is 
making loud or abnormal 
airflow noise

Obstructions in duct work.

Make sure nothing is blocking the vent. Make sureflip over 
and will not fully open when this happens. Adjust to original 
position.

Damper blade on wall or roof cap 
may not be open.

Make sure damper swings freely. Damper blades may flip over 
and will not fully open when this happens. Adjust to original 
position.

Metal grease filter and charcoal 
filter (if present) may be dirty.

Clean the metal grease filter and replace charcoal filter (if 
present). See Care and Cleaning of the Vent Hood.

Insufficient makeup (replacement) 
air

Sufficient makeup (replacement) air is required for 
exhausting appliances to operate to rating. Check with local 
building codes, which may require or strongly advise the 
use of makeup air. Visit 

GEAppliances.com

 for available 

makeup air solutions.

The hood controls are not 
operating correctly

Control logic confused.

Disconnect power to the hood by resetting the circuit 
breaker. Wait 30 seconds to allow controls to reset.

Hood does not appear 
to operate when the 
MEMORY/OFF button 
is pressed. All collars 
around the push buttons 
are illuminated.

The memory feature of this hood 
has not been set. This is normal.

)ROORZSURFHGXUHVIRUVHWWLQJWKH0(025<2))EXWWRQ

Adjust the Fan and Light settings to your preference.

Fan turned on by itself 
and is in MED setting. 
The fan setting can be 
adjusted but not to OFF.

The heat sensor is activated.

This is normal when temperatures below the hood are 
exceeding the heat sensor limits. Remove the heat source 
under the hood or wait until the hood cools to appropriate 
levels. The hood will automatically turn itself off or return 
to its original setting once the heat sensor detects the 
temperature has reached a safe condition.

A collar around a push 
button is not illuminating 
when pressed.

Push button may be stuck.

Check affected push button and ensure that it is not stuck. 
Call for service if problem persists.

Two or more collars 
around the push buttons 
are not illuminating when 
pressed.

Two or more push buttons may be 
stuck.

Check affected push buttons and ensure that they are not 
stuck. Call for service if problem persists.

Sequential presses of the 
LIGHT or FAN buttons will 
change the setting from 
lowest setting to OFF, 
tohighest setting, to OFF, 
to the lowest setting.

This is normal. It is a feature of 
the hood that the LIGHT and FAN 
buttons will cycle around through 
the settings so that you can easily 
set the controls to your desired 
setting.

No action required.

TROUBLESHOOTING TIPS

Содержание Profile PV977

Страница 1: ...NUAL INSTALLATION INSTRUCTIONS ISLAND CHIMNEY VENT HOODS SAFETY INFORMATION 3 USING THE HOOD Light Controls 5 Vent Controls 5 CARE AND CLEANING Metal Grease Filter 6 Charcoal Filter 6 Stainless Steel...

Страница 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Страница 3: ...ust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or i...

Страница 4: ...codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back draft...

Страница 5: ...an levels LOW MED HIGH BOOST and OFF If you continue to press the or buttons the fan will cycle back through the settings NOTE There is an audible beep each time a button is pressed This is normal NOT...

Страница 6: ...recirculating installation only If the model is not vented to the outside the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors The charcoal filter shoul...

Страница 7: ...surface rust tarnish and small blemishes To receive a 2 00 coupon for a trial sample of Bar Keepers Friend Soft Cleanser follow the link below or scan the QR Code barkeepersfriend com ge Use only a l...

Страница 8: ...above the cooking surface The hood installation height above the cooking surface depends upon ceiling height and duct cover limitations The telescopic duct cover conceals the ductwork running from th...

Страница 9: ...nning installation Do not use an extension cord or adapter plug with this appliance Follow National Electrical Codes or prevailing local codes and ordinances Electrical Supply This vent hood must be s...

Страница 10: ...wrapping and other packaging materials TOOLS AND MATERIALS REQUIRED NOT SUPPLIED Pliers LUH FXWWHU VWULSSHU Metal snips Spirit level Aluminized Duct tape Safety glasses 120V 60Hz 15 or 20 Amp 2 wire w...

Страница 11: ...Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Drill 3 16 Pilot Holes Approx 1 1 2 Deep 4 Places 8 1 4 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 10 5 16 To Centerli...

Страница 12: ...rs or it can be installed for recirculating operation Recirculating Kit included with hood 24 Required Min 36 Recommended Max 36 Typical PV977 Upper Duct Cover 29 92 Lower Duct Cover Counter to Hood H...

Страница 13: ...eiling joists as shown 2x4 wood supports are required to support the weight of the hood Arrange cross framing in the ceiling to suit the existing structure Your ceiling joists will be like one of the...

Страница 14: ...Cooktop outline Align duct to center of cooktop EXAMPLE B Install cross framing V PPHWULFDOO RYHU GXFW FRRNWRS centerline 2x4 Cross framing wood supports Top view ceiling joists at angle to front of...

Страница 15: ...dvertent user contact loads The hood support frame will be supported by the 2 x 4 cross framing Ductwork for Installations Vented to the Outdoors Use the shortest and straightest duct route for satisf...

Страница 16: ...as Needed 8 1 4 To Centerline of Pilot Holes 8 1 2 FRONT OF HOOD Cut one 1 2 Dia Wire Access Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Drill...

Страница 17: ...ructure to the upper horizontal support ZLWK PP VFUHZV NOTE Attach the structure to the previously installed upper horizontal support A Upper horizontal support PP VFUHZV B A B STEP 6 INSTALL HOOD ASS...

Страница 18: ...6HFXUH WKH KRXVH ZLULQJ WR WKH MXQFWLRQ ER ZLWK D strain relief not provided Connect the white lead to the branch circuit white lead RQQHFW WKH EODFN OHDG WR WKH EUDQFK FLUFXLW EODFN lead RQQHFW WKH J...

Страница 19: ...QH XSSHU GXFW FRYHU RYHU WKH UHDU RI WKH support assembly The tabs on the edges of the duct cover will slide into a notch on the duct cover support When all 6 tabs on the duct cover are in the notches...

Страница 20: ...not required for this installation LW WKH WDEV DW WKH HQG RI WKH ILOWHU LQWR WKH VORWV LQ left side of the filter opening Lift up the right side of the filter and push gently until the filter locks i...

Страница 21: ...makeup replacement air is required for exhausting appliances to operate to rating Check with local building codes which may require or strongly advise the use of makeup air Visit GEAppliances com for...

Страница 22: ...22 49 2000915 Rev 0 Notes...

Страница 23: ...imited Warranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchan...

Страница 24: ...xtended Warranties Purchase a GE Appliances extended warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime GE Applian...

Страница 25: ...CHIMENEA PARA ISLA INSTRUCCIONES DE SEGURIDAD 3 USO DE LA CAMPANA Controles de la luz 5 Controles de la ventilaci n 5 CUIDADO Y LIMPIEZA Filtro de grasa met lico 6 Filtro de carb n 6 Superficies de ac...

Страница 26: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Страница 27: ...ire sea conducido hacia fuera No ventile el aire de la salida hacia espacios dentro de paredes o cielorrasos o ticos espacios muy bajos o garajes ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES A PERSO...

Страница 28: ...n todos los c digos y normas aplicables incluyendo construcci n con clasificaci n para incendios B Se necesita suficiente aire para una combusti n y escape de gases adecuados a trav s de la ventilaci...

Страница 29: ...e ventilaci n LOW MED medio HIGH BOOST impulso y OFF Si contin a presionando los botones o el ventilador se desplazar a trav s de las configuraciones NOTA Puede o rse un pitido cada vez que se presion...

Страница 30: ...elo no tiene ventilaci n al exterior el aire se recircular a trav s de un filtro de carb n desechable que ayuda a remover humo y olores El filtro de carb n debe cambiarse cuando est evidentemente suci...

Страница 31: ...que as manchas Para recibir un cup n de 2 00 para una muestra de Bar Keepers Friend Soft Cleanser ingrese al siguiente link o escanee el C digo QR barkeepersfriend com ge Use s lo un limpiador l quido...

Страница 32: ...perficie de cocci n depende de la altura del cielorraso y las limitaciones de la cubierta del conducto La cubierta plegable oculta los conductos que van desde la parte superior de la campana hasta el...

Страница 33: ...ADECUADA Quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n No utilice un cable de extensi n o un enchufe adaptador con este artefacto Siga los C digos El ctricos Nac...

Страница 34: ...ENTAS Y MATERIALES REQUERIDOS NO SUMINISTRADOS Alicates Alicate pelacables Tijeras para metal Nivel de burbuja de aire Cinta aislante de aluminio Gafas de seguridad Cable de 120V 60Hz 15 o 20 amperios...

Страница 35: ...re Access Hole as Needed Drill 3 16 Pilot Holes Approx 1 1 2 Deep 4 Places 8 1 4 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 10 5 16 To Centerline of Pilot Holes 31 14772 Printed...

Страница 36: ...ilaci n hacia el exterior o puede ser instalada para un funcionamiento con recirculaci n Se incluye un kit de recirculaci n con la campana 24 Requeridos M n 36 Recomendado Max 36 T pico PV977 Cubierta...

Страница 37: ...2 x 4 para sostener el peso de la campana Coloque el armaz n cruzado en el cielorraso de modo que se ajuste a la estructura existente Las vigas del cielorraso ser n como uno de los siguientes ejemplos...

Страница 38: ...el conducto con el centro de la estufa EJEMPLO B Instale el armaz n cruzado en forma sim trica sobre la l nea FHQWUDO GHO FRQGXFWR HVWXID Soportes de madera del armaz n cruzado de 2 x 4 Top view ceil...

Страница 39: ...rmaz n de la campana tendr el soporte de un armaz n cruzado de 2 x 4 Conductos para instalaciones con ventilaci n hacia el exterior Use el recorrido m s corto y directo para el conducto a fin de logra...

Страница 40: ...as Needed 8 1 4 To Centerline of Pilot Holes 8 1 2 FRONT OF HOOD Cut one 1 2 Dia Wire Access Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Cut one 1 2 Dia Wire Access Hole as Needed Drill...

Страница 41: ...horizontal superior con ORV WRUQLOORV GH NOTA Adhiera la estructura al soporte horizontal superior instalado A Soporte horizontal superior WRUQLOORV GH B A B PASO 6 INSTALE EL ENSAMBLE DE LA CAMPANA...

Страница 42: ...D OD FDMD GH FRQH LRQHV con un alivio de tensi n no provisto Conecte el cable blanco al cable blanco del circuito derivado RQHFWH HO FDEOH QHJUR DO FDEOH QHJUR GHO FLUFXLWR derivado RQHFWH HO FDEOH Y...

Страница 43: ...e del soporte Las leng etas de los extremos de la cubierta del conducto se deslizar n dentro de una ranura del soporte Cuando las 6 leng etas de la cubierta del conducto se encuentran en las ranuras d...

Страница 44: ...UHPR GHO ILOWUR GHQWUR de las ranuras del lado izquierdo de la abertura del filtro Levante el lado derecho del filtro y presione ligeramente hasta que el filtro se trabe en su lugar Verifique que la t...

Страница 45: ...s de la campana no funcionan correctamente Error en el circuito l gico Desconecte la electricidad de la campana re configurando el interruptor de circuitos Espere 30 segundos para que los controles vu...

Страница 46: ...22 49 2000915 Rev 0 Notas...

Страница 47: ...SI N DE GARANT AS IMPL CITAS Su nica y exclusiva alternativa es la reparaci n del producto como se indica en la Garant a Limitada Las garant as impl citas incluyendo garant as impl citas de comerciabi...

Страница 48: ...quiera una garant a extendida de GE Appliances y conozca los descuentos especiales que est n disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Interne...

Отзывы: