25
,QVWDOODWLRQ,QVWUXFWLRQV
D
8&7:25.&$/&8/$7,216
&DOFXODWH7RWDO(TXLYDOHQW'XFWZRUN/HQJWK
Equivalent Number
Equivalent
Duct Pieces
Length* x Used = Length
6” round
straight
1 ft.
x
( )
=
ft.
3
1
ø
4
” x 10”
straight
1 ft.
x
( )
=
ft.
µ
elbow
15 ft. x
( ) =
ft.
µ
elbow
9 ft. x
( )
=
ft.
24” max.
Flexible
Metal Offset
Adapter
34 ft. x
( )
=
ft.
3
1
ø
4
” x 10”
HOERZ
IW [
IW
3
1
ø
4
” x 10”
HOERZ
IW
[
=
ft.
3
1
ø
4
” x 10”
IODWHOERZ IW [
=
ft.
6” round
to 3
1
ø
4
” x 10”
transition
7 ft. x
( ) =
ft.
Subtotal Column 1 =
ft.
*Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good venting
performance with any downdraft cooktop.
0HDVXUHDQGOLVWIHHWRIVWUDLJKWGXFWXVHG&RXQWDQG
list the quantity of all other duct pieces for the “Number
Used” of each type.
,03257$17
For maximum efficiency, use the shortest and straightest
duct run possible, with as few fittings as possible.
)RU
VDWLVIDFWRU\SHUIRUPDQFHWKHGXFWUXQVKRXOGQRW
H[FHHGIHHWHTXLYDOHQWOHQJWK
Venting performance is improved by using larger
diameter duct.
Equivalent Number
Equivalent
Duct Pieces
Length* x
Used = Length
6” round
to 3
1
ø
4
” x 10”
transition
HOERZ
IW [
IW
3
1
ø
4
” x 10”
to 6” round
transition
5 ft. x
( ) =
ft.
3
1
ø
4
” x 10”
to 6” round
transition
HOERZ
IW [
=
ft.
6” round
wall cap
with damper 21 ft. x
( ) =
ft.
3
1
ø
4
” x 10”
wall cap
with damper 27 ft. x
( ) =
ft.
6” round
roof cap
20 ft. x
( ) =
ft.
6” round
roof vent
24 ft. x
( ) =
ft.
Subtotal Column 2 =
ft.
Subtotal Column 1 =
ft.
727$/'8&7:25.
ft.
Should not exceed 100 feet.