NOTE: The only GE approved plastic tubing
is that supplied in GE SmartConnect
™
Refrigerator Tubing kits. Do not use any
other plastic water supply line because the
line is under pressure at all times. Certain
types of plastic will crack or rupture with age
and cause water damage to your home.
•
A GE water supply kit
(containing tubing,
shutoff valve and fittings listed below) is
available at extra cost from your dealer or
from Parts and Accessories, 800.626.2002
(in Canada 1.888.261.3055).
•
A cold water supply.
The water pressure must
be between 20 and 120 p.s.i. (1.4–8.1 bar).
•
Power drill.
•
1/2
″
or adjustable wrench.
•
Straight and Phillips blade screwdriver.
•
Two 1/4
″
outer diameter compression nuts
and 2 ferrules (sleeves)—
to connect the
copper tubing to the shutoff valve and the
refrigerator water valve.
OR
•
If you are using a GE SmartConnect
™
Refrigerator Tubing kit, the necessary
fittings are preassembled to the tubing.
•
If your existing copper water line has a
flared fitting at the end, you will need an
adapter
(available at plumbing supply
stores) to connect the water line to the
refrigerator
OR
you can cut off the flared
fitting with a
tube cutter
and then use a
compression fitting. Do not cut formed end
from GE SmartConnect
™
Refrigerator tubing.
•
Shutoff valve
to connect to the cold water
line. The shutoff valve should have a water
inlet with a minimum inside diameter of
5/32
″
at the point of connection to the
COLD
WATER LINE
. Saddle-type shutoff valves are
included in many water supply kits. Before
purchasing, make sure a saddle-type valve
complies with your local plumbing codes.
WHAT YOU WILL NEED
(CONT.)
Installation Instructions
33
SHUT OFF THE MAIN WATER
SUPPLY
Turn on the nearest faucet long enough
to clear the line of water.
Install the shutoff valve on the nearest
frequently used drinking water line.
1
Choose a location for the valve that is
easily accessible. It is best to connect into
the side of a vertical water pipe. When it is
necessary to connect into a horizontal
water pipe, make the connection to the
top or side, rather than at the bottom,
to avoid drawing off any sediment from
the water pipe.
CHOOSE THE VALVE LOCATION
2
DRILL THE HOLE FOR THE VALVE
3
Drill a 1/4
″
hole in the water pipe (even if
using a self-piercing valve), using a sharp
bit. Remove any burrs resulting from
drilling the hole in the pipe.
Take care not to allow water to drain into
the drill.
Failure to drill a 1/4
″
hole may result in
reduced ice production or smaller cubes.
Содержание Profile CustomStyle PSC23NHS
Страница 86: ...Soutien au consommateur Conseils de d pannage Fonctionnement Mesures de s curit Installation 86 Notes...
Страница 129: ...129 Notas Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n...
Страница 130: ...130 Notas Solucionar problemas Servicio al consumidor Operaci n Seguridad Instalaci n...