GE Profile Advantium PSB9120DFBB Скачать руководство пользователя страница 2

240407

PSB9120DF 

GE Profile

 Series Advantium

® 

120V - 30 in. Wall Oven

 

Specification Revised 7/13

Prepare the opening 
The Advantium 120V series can be installed in combination with 
other GE/Monogram appliances. Always follow each product's 
Installation Instructions to compete the installation.  

Single Oven Installation:  
Order a 30" wide single oven cabinet or cut the opening in a wall 
to the dimensions shown.
*  For existing cutouts, a maximum width 

of 28-1/2" is acceptable. If the opening 
is slightly wider, secure a furring strip 
on each side of the cutout for securing 
the oven.

•  Allow 3/4" to 2-1/8" case trim overlap 

on the sides and 7/8" overlap on the 
bottom of the opening for all models. 
The amount of overlap on the sides 
depends on the actual cutout width. 
Allow 1-1/4" case trim overlap on the 
top for models PSB9120 and for models 
ZSC1201 and ZSC1202.

•  Oven overlaps will conceal cut edges on all sides of the opening.

Note: PSB9120 series Advantium can be installed below GE/GE Profile 
non-downdraft gas and electric cooktops. It CANNOT be installed below 
induction or Monogram (2GU3841385) gas cooktops.

Note: PSB9120 series Advantium oven comes with two lower trim 
pieces. One is for use above 36-inch height installations and one is 
for use below 36-inch installations. Use of the accessory drawer will 
replace the bottom trim piece for applicable installations. Please see 
installation instructions for full details.

Prepare the opening (cont.)
When installed over a single oven or a 
warming drawer, allow at least 2" between 
the two openings. This separation will 
provide clearance for bottom overlap of the 
Advantium and the other appliance overlaps.
Construct a solid oven floor of 3/8" min. thick 
plywood supported by 2 x 4 or 2 x 2 runners 
on all sides.
•  the support must be level and rigidly 

mounted, flush with the bottom edge of 
the cutout.  

Note: Additional clearances between the 
cutouts may be required. Check to be sure the 
oven supports above the Warming Drawer 
location do not obstruct the required interior 
depth and height. See Warming Drawer 
installation instructions for details.

Installation over a GE/Monogram Oven 

and Warming Drawer:

Note: Additional clearances between the 
cutouts may be required. Check to be sure the 
oven supports above the Warming Drawer 
location do not obstruct the required interior 
depth and height. See Warming Drawer 
installation instructions for details.

CAutION: For personal safety, the mounting 
surface must be capable of supporting the 
cabinet load, in addition to the added weight 
of this approximate 80-pound oven and 30-
pound drawer, plus additional oven loads of up 
to 50 pounds or a total weight of 160 pounds.

Preparation WIth an Accessory Drawer

Installation over a GE/Monogram 

Warming Drawer:

30”

23-1/2”

25-1/4”

Min.

21”

2” Min. 
(3” recommended)

Per warming

drawer

requirement

Construct

Solid Bottom 

Min. 3/8”

Plywood

Supported

by 2x4 or 2x2

Runners all 

Four Sides

5” min. 

from floor

1” min. 

above 

toekick

Warming Drawer:

Construct Solid

Bottom Min.

3/8” Plywood

Supported by 

2x4 or 2x2

Runners all 

Four Sides

30”

23-1/2”

21”

2” Min.

Per Oven

Requirement

Per warming drawer requirement

2” Min. 
(3” recommended)

25-1/4”

Min.

5” min. 

from floor

1” min. 

above 

toekick

30”

23-1/2”

25-1/4”

Min.

21”

Construct

Base

Min. 3/8”

Plywood

Supported

by 2x4 or 2x2

Runners all

Four Sides

5” min. 

from floor

1” min. 

above 

toekick

Отзывы: