– 61 –
Service Mode Tes
t
Sequence
t14 Spin Test
Enter
Displays “estimated” and “current” rpm. Unit begins spinning at 410 rpm.
Start
Ramps up to 1050 rpm.
Start
Ramps up to 1150 rpm.
Start
Ramps up to 1300 rpm.
Power
Ramps down and returns to service mode screen.
t15 Dispenser
Test
Enter
Displays “pre-wash” and dispenser moves to position 1.
Start
Displays “main detergent” and dispenser moves to position 2.
Start
Displays “fabric softener” and dispenser moves to position 4.
Start
Displays “bleach” and dispenser moves to position 3.
Start
Repeats above sequence, starting with “main detergent.”
Power
Drains and returns to service mode screen.
t16 Bulk Pumps
Test
Enter
Displays “left detergent pump;" water
fi
lls and primes left detergent.
Start
Displays “softener pump” and begins priming.
Start
Displays “right det pump” and begins priming.
Start
Continues cycling through the bulk pumps.
Power
Drains and returns to service mode screen.
t17 Bulk Sensors
Test
Enter
Displays the status of Left Detergent, Softener and Right Detergent.
Power
Returns to service mode screen.
t18 Auto Spin
Pro
fi
le
Enter
Slowly ramps up to 90, then 120, then 410.
Power
Interrupts and returns to service mode screen.
t19 Bulk Manual
Priming
Enter
Displays “prime left detergent,” “prime softener,” "prime right detergent”
with one highlighted.
Enter
Begins priming selected, with water on to rinse it from dispenser drawer.
Power
Drains; then returns to service mode screen.
t20 Bulk Primed
Status
Enter
Displays “left detergent pump,” “softener pump,” "right detergent pump”
with one highlighted.
Enter
Displays “left det primed status;" choose status “yes” (lines primed) or
“no” (lines not primed).
Enter
Returns back to “Bulk Primed Status.”
Power
Returns to service mode screen.
t21 Steam
Enter
Displays "Steam" tumbles at 43 rpm in 15/3/15 increments. Enables
steam generator throughout duration of test.
Power
Steam Generator turns off, drum stops, returns to service mode screen.
t22 Overnight
Ready
Enter
Unit begins a slow tumble clockwise then counterclockwise. Overnight
ready fan is energized.
Power
Returns to service mode screen.
t23 OOB Test
Enter
The unit spins at a low RPM and displays the out of balance number
measured by the inverter. Check 255 means the inverter has not yet
checked the out of balance value. Once the 255 is updated, any number
below 15 is normal out of balance operation. Any number between 15
and 20 is marginally acceptable. Any number greater than 20 means an
abnormal out of balance is detected.
Power
Returns to service mode screen.
t24 Slow Ramp
Test
Enter
Slowly ramps to the maximum spin speed.
Power
Returns to service mode screen.
Содержание PFWS4600L0
Страница 9: ...9 Continued Next Page...
Страница 11: ...11 Continued Next Page...
Страница 13: ...13 Continued Next Page...
Страница 14: ...14 Continued Next Page...
Страница 19: ...19...
Страница 22: ...22 Dispenser Drawer Tub Drive Pulley Belt Motor Rear View Front View Con t...
Страница 65: ...65 Schematics Model 4600 with Steam...
Страница 66: ...66 Model 4400 without Steam...