![GE PFWS4400L0 Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/ge/pfws4400l0/pfws4400l0_technical-service-manual_134025052.webp)
– 52 –
9. Pull the tub gasket off the outer tub lip.
Note:
When reinstalling the tub gasket on the outer
tub, align the indicators on the top and the bottom
of the gasket with the arrows located on the top and
the bottom of the tub.
Outer
Tub Lip
Indicator
Arrow
Top of Gasket
Bottom of Gasket
Indicator
Arrow
Damper
Wrench
Location
Dampers
Each of the 4 dampers is secured to the outer tub
by a gray upper bushing that locks in a slot in the
outer tub. Each damper is held to the chassis with a
plastic pin.
To remove the dampers:
Caution:
Do not twist the damper cylinder by
hand to remove. Stress may result in the damper
developing noise at a later date.
1. Remove the service panel. (See
Service Panel
.)
2. Rotate the gray upper bushing a quarter-turn
clockwise (as viewed from the top) using a 6-in.
adjustable crescent wrench with a jaw opening
of approximately 7/8 inch.
3. Depress and remove the damper from the slot in
the outer tub.
Gray Upper
Bushing
(Continued Next Page)
Содержание PFWS4400L0
Страница 9: ... 9 Continued Next Page ...
Страница 11: ... 11 Continued Next Page ...
Страница 13: ... 13 Continued Next Page ...
Страница 14: ... 14 Continued Next Page ...
Страница 19: ... 19 ...
Страница 22: ... 22 Dispenser Drawer Tub Drive Pulley Belt Motor Rear View Front View Con t ...
Страница 65: ... 65 Schematics Model 4600 with Steam ...
Страница 66: ... 66 Model 4400 without Steam ...