Placetheunitonaplatformortableevenwiththecutoutopening.Theplatformmustsupport200lbs.(91kg).
Connecttheflexibleconduittotheelectricaljunctionboxasfollows:
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE
:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,
Electrical
Requirements
.
Whenconnectingtoathree-conductorbranchcircuit,iflocalcodespermit:
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE
:Ifresidenceleadsorgroundarealuminumconductors,seeWARNINGinsection5A,
Electrical
Requirements
.
Whenconnectingtoafour-conductorbranchcircuit,iflocalcodespermit:
1.
Connectthebareovengroundconductorwiththe
crimpedneutral(white)leadtothebranchcircuit
neutral(whiteorgrayincolor),usingwirenuts.
2.
Connecttheovenredleadtothebranchcircuitred
lead,andtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
3.
Installproperstrainreliefclamp.
4.
Installjunctionboxcover.
1.
Cuttheneutral(white)leadfromtheclamp.Re-strip
theneutral(white)leadtoexposetheproperlength
ofconductor.
2.
Attachtheappliancegroundinglead(greenorbare
copper)inaccordancewithlocalcodes.
3.
Connecttheovenneutral(white)leadtothebranch
circuitneutral(whiteorgray)inaccordancewith
localcodes,usingawirenut.
4.
Connecttheovenredleadtothebranchcircuitred
leadandtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
5.
Installproperstrainreliefclamp.
6.
Installjunctionboxcover.
Branch
circuit
Black
Alternate
knockout
Neutralbarewire
connection
Rangeconduit
snapsintobox
Red
Groundand
neutralwires
(white)
Branch
circuit
Black
Alternate
knockout
Rangeconduit
snapsintobox
Red
White
Ground
wires
6
InstallationInstructions
5B
MAKE ELECTRICAL CONNECTIONS