background image

3

  ELECTRICAL REQUIREMENTS

WARNING

 This appliance must be properly grounded.

WARNING

 All new constructions, mobile homes, recreational vehicles and installations 

where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.

WARNING

 To prevent fire or shock, do not use an extension cord with this appliance. 

WARNING

 To prevent shock, remove house fuse or open circuit breaker before 

beginning installation.

We recommend you have the electrical wiring and hookup of your range connected by a qualified 
electrician. After installation, have the electrician show you how to disconnect power from the range.

You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you 
connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring 
must be used.

Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) 
utilize a 4-conductor connection to an electric range. When installing an electric range in new 
construction, mobile home, recreational vehicle, or an area where local codes prohibit grounding 
through the neutral conductor, refer to the section on four-conductor branch circuit connections.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven 
according to governing codes could result in a hazardous condition. If there are no local codes, 
your oven must be wired and fused to meet the National Electrical Code, NFPA No. 70 – latest 
edition, available from the National Fire Protection Association.

This appliance must be supplied with the proper voltage and frequency, and connected to an 
individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker or 
time-delay fuse.

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with 
ring terminals on wire and a strain relief device.

A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord 
is not recommended but if used, it should be marked for use with nominal 1

3

»

8

” diameter connection 

openings. Care should be taken to center the cable and strain relief within the knockout hole to 
keep the edge from damaging the cable.

The rating plate is located on the oven frame or on the side of the drawer frame.

NOTE:

 Use of automatic, wireless or wired external switches that shut off power to the appliances, 

are not recommended for this product.

Rating plate

SINGLE OVEN

4

  POWER CORD AND CONDUIT INSTALLATION

A

   Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You 

can access the terminal block by either removing a terminal block cover (on some models) or 
the wire cover. Do not discard these screws.

B

   For power cord and 1” conduit only, remove 

the knockout ring (1

3

»

8

”) located on bracket 

directly below the terminal block. To remove 
the knockout, use a pair of pliers to bend the 
knockout ring away from the bracket and 
twist until ring is removed.

D

   For 3/4” conduit installations only, purchase a squeeze connector matching the diameter  

of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector  
and tighten. Allow enough slack to easily attach the wires to the terminal block. 

NOTE:

 Do 

not install the conduit without a squeeze connector. The squeeze connector MUST be 
installed before reinstalling the rear terminal block.

Knockout 
ring in 
bracket

Knockout ring 
removed

Terminal block 
(appearance  
may vary)

C

   For power cord installations only (see 

the next step if using conduit), assemble 
the strain relief in the hole. Insert the 
power cord through the strain relief and 
tighten. Allow enough slack to easily 
attach the cord terminals to the terminal 
block. If tabs are present at the end of 
the winged strain relief, they can be 
removed for better fit.

 

 

NOTE:

 Do not install the power cord 

without a strain relief. The strain relief 
bracket MUST be installed before 
reinstalling the rear range wiring cover.

Power cord

Strain relief

Terminal 
block

Bracket

Squeeze 

connector

Terminal block

Conduit

Bracket

Proceed to step 6 or 7.

Rear of Range

Terminal 

Block Cover

Screws to 
remove terminal 
block cover

Содержание PB900YVFS

Страница 1: ...ound the range can withstand the heat up to 200 F generated by the range 0 to cabinets below cooktop and at the range back B Allow 30 minimum clearance between surface units and bottom of unprotected...

Страница 2: ...required A 50 amp range cord is not recommended but if used it should be marked for use with nominal 13 8 diameter connection openings Care should be taken to center the cable and strain relief within...

Страница 3: ...Do not loosen the upper screws B Remove the ground screw and ground plate and retain them C Cut the ground strap below the terminal block and discard the lower section D Insert the ground screw throu...

Страница 4: ...Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted into the Anti Tip bracket and that the bracket is securely installed OPERATION CHECKLIST Check tha...

Страница 5: ...s si la estufa se mueve de lugar Si esto no se hace se podr producir la muerte o quemaduras graves en ni os o adultos Riesgo de Ca da ADVERTENCIA 2 C MO PREPARAR LA ABERTURA PARA USO EN EL INTERIOR SO...

Страница 6: ...clasificado para 40 amperios con rango de voltios m nimo de 125 250 No se recomienda un cable de 50 amperios pero si se utiliza debe se alizarse para usarse con aberturas de conexi n de un di metro no...

Страница 7: ...n a tierra que est debajo del bloque terminal y descarte la secci n inferior D Inserte el tornillo de conexi n a tierra a trav s de la placa de conexi n a tierra retirada anteriormente y nuevamente en...

Страница 8: ...bien introducida dentro del soporte anti volcaduras y que el soporte se encuentre bien instalado LISTA DE CONTROL DE FUNCIONAMIENTO Controle que el control del horno funcione correctamente Si el contr...