6.
Slide the liquid end assembly off of the pump shaft, taking care not to bend
the pump shaft.
7.
Remove the retaining ring and remove. The rotary head of the mechanical
seal.
8.
Remove the seal holder along with the stationary seal seat.
9.
Remove the four (4) 3/8-16NC bolts that hold the motor adapter to the motor,
and remove the motor adapter.
10.
Remove the pump shaft assembly where it is screwed to the threaded motor
shaft by first heating the joint area to loosen the thread-locking compound.
Secure the motor shaft using a vise grip, and loosen the pump shaft assem-
bly. An impeller may be used to grip the shaft, taking proper care not to dam-
age the impeller. Or, use a vise grip and fabric rug to grip the splined shaft,
taking care not to damage the splines.
11.
The motor can now be serviced by a qualified service center, or replaced.
5.5
Motor Installation: X Motor Adapter Pumps
STEPS
1.
To re-use a repaired motor, clean the threads on the shaft of any thread-
sealant residue.
2.
Reinstall the pump shaft onto the threaded motor shaft until fully seated.
Rotate the pump shaft to make sure it runs true. Run-out should be less than
0.03 inch (0.76 mm) for every 10 inches of pump shaft length.
3.
Loosen the pump shaft from the motor shaft, apply thread sealant to the
threads, and tighten the shaft again until fully seated. Use standard strength
thread sealant on single-phase motors, and a high-strength thread sealant on
three-phase motors.
4.
Install the motor adapter onto the motor and install and tighten the four bolts
into the motor.
5.
Position the seal holder into the motor adapter, using Vaseline or grease on
the O-ring as a lubricant. Replace the O-ring if damaged.
6.
Install a new mechanical seal stationary seat, using Vaseline, grease, or water
as a lubricant on the rubber portion.
7.
Install the rotary portion of the mechanical seal using a small amount of
Vaseline lubricant on the round body of the shaft, and also on the face of the
ceramic seat face where the carbon wear ring contacts it.
19
Содержание OSMONICS TONKAFLO SS1000 SERIES
Страница 2: ......
Страница 6: ......
Страница 17: ...Figure 3 4 Rolling the Leads to Balance Current Draw 11 ...
Страница 20: ...Figure 4 5 Removal of Pump Liquid End from Figure 4 6 Removal of Mechanical Seal Holder from Motor Adapter 14 ...
Страница 29: ...8 0 DIMENSIONAL DRAWINGS 8 1 500X Motor Adapter Pumps Figure 8 8 500X Motor Adapter Pump 23 ...
Страница 30: ...8 2 500 XB Motor Adapter Pumps Figure 8 9 500 XB Motor Adapter Pump 24 ...
Страница 31: ...8 3 1000X and 1800X Motor Adapter Pumps Figure 8 10 1000X and 1800X Motor Adapter Pump 25 ...
Страница 32: ...8 4 1800XB Motor Adapter Pumps Figure 8 11 1800XB Motor Adapter Pump 26 ...
Страница 33: ...8 5 1800XC Motor Adapter Pumps Figure 8 12 1800XC Motor Adapter Pump 27 ...
Страница 34: ...9 0 CUTAWAY DRAWINGS 9 1 X Motor Adapter Pump Figure 9 13 X Motor Adapter Pump 28 ...
Страница 35: ...9 2 XB and XC Motor Adapter Pump Figure 9 14 XB and XC Motor Adapter Pump 29 ...
Страница 41: ......