NX-1348E-ICON
- 9 -
g
GE Interlogix
KEYPAD FUNCTIONS
Arming your system in the “AWAY” mode
AWAY is used when the user is away from the premise and wants the interior protected.
Close all protected doors and windows.
Step 1
•
Ready
icon will be on or flashing when all protected zones and sensors are secure.
NOTE:
If any
zones are bypassed, a sensor in that zone can be violated without affecting the
ready
icon
.
•
The security system will not arm if the
not
ready
icon
is on or flashing.
•
If the
power
icon is off, you have no AC power. Restore power if possible. If not, contact your
installing company.
Step 2 Enter your 4 or 6 digit user code to arm the system.
•
The
armed
icon and
exit
led will illuminate.
•
You may now leave the building.
NOTE:
The exit led will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time
is about to expire. The user may wish to disarm and rearm the system if more time is needed.
Arming your system in the “STAY mode”
STAY is used when the user is inside the premise and wants protection around the perimeter.
Close all protected doors and windows.
Step 1
•
Ready
icon must be on or flashing when all protected zones and sensors are secure.
NOTE:
If any
zones are bypassed, a sensor in that zone can be violated without affecting the
ready
icon
.
•
The security system will not arm if the
not ready
icon
is on or flashing.
•
If the
power
icon is off, you have no AC power. Restore power if possible. If not, contact your
installing company for service.
Step 2
•
Enter your 4 or 6 digit user code.
•
If “Auto Bypass” is enabled, all interior zones will be bypassed if you do not leave through
designated entry/exit door. If Auto Bypass is enabled, omit Step 3.
•
When “Auto Instant” is enabled, if you do not leave through a designated entry/exit door the
instant
icon will illuminate indicating that the entry/exit doors no longer have an entry delay. If “Auto
Instant” is enabled, omit Step 4.
Step 3
•
Press the [
STAY
] key.
•
The
stay led
will illuminate indicating that all interior zones are bypassed. (All interior devices will
bypass automatically, giving the user freedom of movement within the interior area.)
•
The
bypass led
will illuminate if any zone(s) are bypassed. If any zone(s) have been bypassed
previously by the user, the icon(s) corresponding to the bypassed zone(s) will illuminate, alerting the
user that a zone(s) may be unprotected and can be faulted without an alarm.
Step 4
•
To toggle from a “delayed entry” mode to an “Instant” mode, press the [
STAY
] key again.
•
The
instant
icon will illuminate indicating that the entry/exit doors have no entry delay.