B-72
G60 Generator Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
D351
IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value
0 to 2
---
1
F001
1
D352
IEC 61850 GGIO2.CF.SPCSO51.ctlModel Value
0 to 2
---
1
F001
1
D353
IEC 61850 GGIO2.CF.SPCSO52.ctlModel Value
0 to 2
---
1
F001
1
D354
IEC 61850 GGIO2.CF.SPCSO53.ctlModel Value
0 to 2
---
1
F001
1
D355
IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value
0 to 2
---
1
F001
1
D356
IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value
0 to 2
---
1
F001
1
D357
IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value
0 to 2
---
1
F001
1
D358
IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value
0 to 2
---
1
F001
1
D359
IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value
0 to 2
---
1
F001
1
D35A
IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value
0 to 2
---
1
F001
1
D35B
IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value
0 to 2
---
1
F001
1
D35C
IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value
0 to 2
---
1
F001
1
D35D
IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value
0 to 2
---
1
F001
1
D35E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
0 to 2
---
1
F001
1
D35F
IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value
0 to 2
---
1
F001
1
Remote Device Status (Read Only) (16 modules)
D380
Remote Device 1 StNum
0 to 4294967295
---
1
F003
0
D382
Remote Device 1 SqNum
0 to 4294967295
---
1
F003
0
D384
...Repeated for Remote Device 2
D388
...Repeated for Remote Device 3
D38C
...Repeated for Remote Device 4
D390
...Repeated for Remote Device 5
D394
...Repeated for Remote Device 6
D398
...Repeated for Remote Device 7
D39C
...Repeated for Remote Device 8
D3A0
...Repeated for Remote Device 9
D3A4
...Repeated for Remote Device 10
D3A8
...Repeated for Remote Device 11
D3AC
...Repeated for Remote Device 12
D3B0
...Repeated for Remote Device 13
D3B4
...Repeated for Remote Device 14
D3B8
...Repeated for Remote Device 15
D3BC
...Repeated for Remote Device 16
Phasor Measurement Unit Basic Configuration (Read/Write Setting)
D400
PMU 1 Function
0 to 1
---
1
F102
0 (Disabled)
D401
PMU 1 LDInst
---
---
---
F214
"PMUx"
D422
PMU 1 IDcode
1 to 65534
---
1
F001
1
D423
PMU 1 STN
---
---
---
F203
"GE-UR-PMU"
D42B
PMU 1 Source
0 to 5
---
1
F167
0 (SRC 1)
D42C
PMU 1 Class
0 to 2
---
1
F549
1 (M-CLASS)
D42D
PMU 1 Format
0 to 1
---
1
F547
0 (Integer)
D42E
PMU 1 Style
0 to 1
---
1
F546
0 (Polar)
D42F
PMU 1 Rate
0 to 13
---
1
F544
4 (10/sec)
D430
PMU 1 PHS-x (14 items)
0 to 14
---
1
F543
1 (Va)
D43E
PMU 1 PHS-x Name (14 items)
---
---
---
F203
"GE-UR-PMU-
PHS 1 "
D4AE
PMU 1 A-CH-x (16 items)
0 to 65535
---
1
F600
0
D4BE
PMU 1 A-CH-x (16 items)
---
---
---
F203
"AnalogChannel 1
"
D53E
PMU 1 D-CH-x (16 items)
0 to 4294967295
---
1
F300
0
D55E
PMU 1 D-CH-x Name (16 items)
---
---
---
F203
"Dig Channel 1 "
D5DE
PMU 1 D-CH-x Normal State (16 items)
0 to 1
---
1
F108
0 (Off)
D5EE
PMU 1 Reserved (17 items)
0 to 1
---
1
F001
0
Contact Outputs (Read/Write Setting) (64 modules)
DC90
Contact Output 1 Name
---
---
---
F205
“Cont Op 1"
Table B–10: MODBUS MEMORY MAP (Sheet 64 of 68)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...