GE Monogram ZVB36 Скачать руководство пользователя страница 2

Содержание Monogram ZVB36

Страница 1: ...Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 J31 i0728 3 J 07 11 GE ...

Страница 2: ...RK WA RN I N G TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before service or cleoning unit switch power off ot service ponel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnect...

Страница 3: ... Install Downdraft Vent 11 Step 2 Install the Ductwork 11 Step 3 Install Remote Switch 12 Step 4 Connect Power 13 Step 5 Install Filters Check Operation 13 Cleaning 13 PRODUCT DIMENSIONS A B 30 Models 30 28 5 16 36 Models 36 33 15 16 A B _i t 23 5 8 1 1 2_ 8 1 2 Lift 1 4 _ 2 1 4 _i 32 3 8 ACCESSORIES J RB67 Optional accessory for indoor remote location of the blower motor assembly Use this kit whe...

Страница 4: ...erior cabinet depth will house the cooktop burner box the vent and the cutout clearance from the front 5 When countertop and cabinet depth resent a problem review Creative Solutions Read this book completely to accurately plan the installation locution clearances and ductwork requirements With careful planning you can achieve a custom look with minimal adjustments Creative Solutions When the kitch...

Страница 5: ...und Ductwork lUST be vented to the outside never into a crowl space ottic or other enclosed spoce Determine the need for o woll cop or roof cop Order the cop in odvonce Electrical and Gas Locations Plan the placement of the electrical outlet and gas connections if used carefully Electrical outlets Gnd gGs connections cannot be placed on the back wall of the cabinet becGuse it may interfere with th...

Страница 6: ...h to ensure that adequate fiat countertop surface is available For cooktop and downdraft combination depth Follow cooktop installation instructions for cooktop and downdraft combination installation Otherwise add 2 5 4 to the cooktop cutout depth NOTE Add 2 7 8 to the cooktop cutout depth for JP328 and JP626 3 8 Minimum fiat counter top behind cutout required Required to maintain UL or CSAapproval...

Страница 7: ...2 Filters 2 Stabilizing Brackets With Screws i 1 Wire and White Connector TOOLS AND MATERIALS REQUIRED Large flat blade screwdriver Jigsaw Carpenter s square Ductwork to suit the installation Level REMOVE PACKAGING Remove the shipping materials and the carton set carton aside The carton can be used as a pad when changing or adjusting vent direction ...

Страница 8: ...ed on the back of the cabinet wall where it may interfere with the downdraft plenum The downdraft vent power cord is to be routed beneath the cooktop and routed away from heat generated by the cooktop Ensure that the cooktop is installed per manufacturer s installation instructions Locate the Gas or Electrical Connection Only Within the Shaded Area I J DO NOT Locate 2_9 1 2 Gas or Electrical Conne...

Страница 9: ...pping box to use as a pad Lay the vent on its back and onto the pad To change to a left or right discharge Remove the 4 screws holding the blower and the mounting plate assembly to the downdraft vent Retain screws Remove blower assembly turn it over to access the 4 nuts holding the blower to the mounting plate Remove the nuts IMPORTANT Do not lift motor by the power cable Turn the blower to the le...

Страница 10: ...terruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE Duct Piece _ 6 90 elbow Z2 ft _ 6 45 elbow 7 ft _ 3 1 4 x 20 90 elbow 14 ft 3 1 4 x 10 45 elbow 8 ft 3 1 4 x 20 90 fiat elbow 33 ft _ _ 6 round to 3 1 4 x lO transition 2 ft _ 3 1 4 x 20 round to 6 transition 2 ft _ 6 round to 3 1 4 x 20...

Страница 11: ...t 3 to 5 times to ensure proper installation _ INSTALL DUCTWORK The downdraft blower system is designed for use with 3 1 4 x 10 ductwork It can be transitioned to 6 round o Ductwork MUST be vented to the outside never in a crawl space attic or other enclosed space o 6 PVC duct should be used when installing under a concrete slab NOTE Local building code must be followed for installation in specify...

Страница 12: ... countertop such that the switch connectors stay located in the 1 2 dia hole Stick adhesive wire clamp near the 1 2 dia hole and attach the loose wire with a wire tie Strain Relief Adhesive wire clamp with tie Control Box Mating Connectors Remote Harness Remote Switch Foam Piece With Adhesive Mounting _ Surface _ _ 2 Dia Hole Strain Relief I_ _ Adhesive wire clamp _ _ _ with tie _ _ _ f If Remote ...

Страница 13: ... to start the blower Adjust the blower by pressing HIGHER or LOWER To lower the vent press the ON OFF pod NOTE It is not necessary to turn the fan OFF before lowering the vent The fan will automatically turn off when the vent is lowered When the fan is not turned off before lowering the vent it will automatically come on at the previously set speed when the vent is fully raised IMPORTANT The vent ...

Страница 14: ...Notes 14 ...

Страница 15: ...Notes 15 ...

Страница 16: ...hould be worn NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice J31 i0728 3 06 11 GE GE Consumer Industrial Appliances General Electric Company Louisville KY 40225 GEAppliances com ...

Отзывы: