Installation

Professional Vent Hoods

5

Step

Connect
Electrical

Verify that power is turned off at the source.

CAUTION

If house wiring is not 2-wire with a
ground wire, a ground must be
provided by the installer.
When house wiring is aluminum,
be sure to use U.L. approved anti-
oxidant compound and alumi-
num-to-copper connectors.

WARNING

• Connect white lead to branch circuit white

lead.

• Connect black lead to branch circuit black

lead.

• Connect green lead to branch circuit green

or bare ground lead.

• Secure all connections with wire nuts on

each electrical connector.

Duct Tape
Over Seam and Screw

Screw

Air

Flow

Cut a length of duct to connect hood flange to
the ductwork.
• Install ductwork, making connections in

direction of airflow as illustrated.

• Secure joints in ductwork with sheetmetal

screws.

• Wrap joints with duct tape for airtight seal.

Transition duct pieces are available for 48"
wide models.
ZX48AY, 4-1/2" x 18-1/2" transition to 10"
round straight up exhaust.
ZX48BY, 4-1/2" x 18-1/2" transition to 10"
round direct to rear exhaust.
Call your GE Dealer to order.

Connect
Ductwork

Step

6

Hold the liner below the installed hood.
• Reconnect the male/female connector plug

to heat lamp and one to blower.

• Carefully, slide liner into installed hood.
• While holding in place, re-install the original

screws. Make sure that all screws have been
re-installed.

• Re-install light assembly with original screws.

7

Step

Reassemble
Hood

Reconnect Male/Female
Connector Plug

Connect to
Junction Box

Replace Screws That 
Hold Inner Liner in Place.

To Blower Motor

Hood Inner Liner

Содержание Monogram ZV881WSS

Страница 1: ...GE Monogram Installation Instructions Professional Vent Hoods 48 Models ZV881WSS ZV891YSS ZV880WSS ZV890YSS 36 Models ZV671WSS ZV681YSS ZV670WSS ZV680YSS 30 Models ZV370YSS ZV371YSS...

Страница 2: ...CTRIC SHOCK OR INJURY TO PERSONS OB SERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any ques tions contact the manufacturer B Before servicing or cleani...

Страница 3: ...ct Covers Style Hood Model 6 Duct Cover 12 Duct Cover A Oval ZV881WSS ZV880WSS ZX6DC48WSS 6 Hx27 3 8 Wx10 1 4 D ZX12DC48WSS 12 Hx27 3 8 Wx10 1 4 D A Oval ZV671WSS ZV670WSS ZX6DC36WSS 6 Hx22 1 2 Wx9 3...

Страница 4: ...llation Product Dimensions Clearances The rating plate is located behind filter cutouts To verify your model number remove filters 18 35 25 47 7 8 12 18 23 25 35 7 8 12 18 47 7 8 25 47 7 8 12 ZV891YSS...

Страница 5: ...ll be much easier if the vent hood is installed before the range or cooktop below Decorative Duct Covers Decorative duct covers are available for all models The duct covers conceal the ductwork runnin...

Страница 6: ...uivalent lengths Maximum duct length 100 foot for range hoods Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct s...

Страница 7: ...iner Light Assembly Remove the Packaging and Disassemble 1 Cut and remove the plastic banding on the crate and one holding the parts box Remove the top of the crate by backing out screws Break away cr...

Страница 8: ...ALLATION UNDER A SOFFIT SKIP THIS STEP IF SOFFIT IS NOT USED Cut 2 wood shims 2 x 10 X drywall thickness Secure to the bottom of the horizontal studs flush with the front as illustrated NOTE If drywal...

Страница 9: ...STEPS IF SOFFIT IS USED C Hood Centerline 13 for 48 wide models 9 for 36 wide models 8 15 16 for 30 wide models Rear View of Vent Hood 48 Model Shown Hood Centerline C C C L 6 or 12 Duct Cover Ceilin...

Страница 10: ...6 1 8 8 1 4 6 1 4 6 1 8 8 1 4 3 1 2 3 1 2 2 1 4 2 3 4 35 4 1 2 12 Junction Box 48 Hood Top View Front Side Back Side ZV671WSS ZV670WSS ZV881WSS ZV880WSS ZV891YSS ZV890YSS ZV371YSS ZV370YSS 8 1 2 5 1...

Страница 11: ...4A Step Install Hood Onto Wall WALL MOUNT INSTALLATION SKIP THESE STEPS IF SOFFIT IS USED ZV671WSS ZV670WSS ZV681YSS ZV680YSS ZV881WSS ZV880WSS ZV891YSS ZV890YSS 8 15 16 8 15 16 C L 6 or 12 Duct Cover...

Страница 12: ...l ductwork making connections in direction of airflow as illustrated Secure joints in ductwork with sheetmetal screws Wrap joints with duct tape for airtight seal Transition duct pieces are available...

Страница 13: ...Duct Covers Install one side piece to the top of the hood with 2 screws Install opposite side piece Secure front panel to the side panels with 2 torx screws on each side provided Place the filter drip...

Страница 14: ...14 Notes Professional Vent Hoods...

Страница 15: ...15 Notes Professional Vent Hoods...

Страница 16: ...or goggles should be worn To obtain specific information concerning any Monogram product or service call GE Answer Center consumer information service at 800 626 2000 any time day or night For Monogra...

Отзывы: