Duct Cover

The duct cover consists of two telescoping sections. 
The lower section is attached to the canopy. The 
upper section is attached to a duct bracket or air 
defl ector (depending on installation).

To remove the duct cover:

1.   Remove the grease fi lters. (See 

Filters.

)

Caution: 

When removing the 2 upper mounting 

screws, DO NOT let the upper duct section fall into 
the lower duct section. Damage to the canopy can 
occur.

2.   Remove the two Phillips-head screws (one on 

each side) that attach the upper section of the  
duct cover to the duct bracket or air defl ector 
(depending on installation).

3.   Carefully lower the upper duct section into the 

lower duct section.

5.  Grasp both sections of the duct cover, and lift it 

up to clear the canopy.

 4.  Remove the two Phillips-head screws that 

attach the lower section of the duct cover to the 
canopy.

One 

Screw on 

Each Side

Содержание MONOGRAM ZV800SJSS

Страница 1: ...MODEL SERIES ZV800SJSS ZV800BJBB TECHNICAL SERVICE GUIDE GE Consumer Industrial Monogram 36 in Chimney Vent Hood PUB 31 9132 03 05...

Страница 2: ...avoid personal injury disconnect power before servicing this product If electrical power is required for diagnosis or test purposes disconnect the power immediately after performing the necessary chec...

Страница 3: ...Motor Assembly 17 Filters 10 Glass Visor 8 Installation Information 7 Introduction 4 Lights 12 Light Receptacles 13 Nomenclature 5 Power Supply Housing 15 Push Button Assembly 12 Push Button Controls...

Страница 4: ...py is sleekly styled with a streamlined design seamless nished edges and front mounted touch controls Powerful ventilation A four speed 500 CFM fan blower with boost option captures the smoke and stea...

Страница 5: ...tter designating the year repeats every 12 years Example T 1974 T 1986 T 1998 Z V 800 S J SS Monogram J Model Year S Stainless Steel B Black Features Vent SS Stainless Steel BB Black on Black Nomencla...

Страница 6: ...washers used to complete a path to ground are removed for service they must be returned to their original position and properly fastened GROUNDING SPECIFICATIONS Ground Path Resistance 0 10 Max Insul...

Страница 7: ...t installation Custom cabinet modi cation is required for recirculating operation Installation Information The vent hood is heavy Adequate structural support should be provided in all types of install...

Страница 8: ...Grasp the visor and pull it out to remove steam more ef ciently when cooking Push it back when not in use The vent fan and lights work with the visor in or out Cleaning To preserve and protect the ne...

Страница 9: ...pply Housing Cover Canopy Visor Light Fan assembly Light 3 2 4 1 5 Power Supply Housing Components 1 Transformer 2 Triac 3 PTC Board 4 Capacitor 5 Power Control Board PCB Front View Shown with decorat...

Страница 10: ...d to the outside the air will be recirculated through an additional single disposable charcoal lter that helps remove smoke and odors To remove the charcoal lter rst remove the 2 grease lters Grasp th...

Страница 11: ...track inward to clear the canopy then remove it 6 Remove the 2 Phillips head screws that attach the ribbon receptacle to the left track 7 Remove the single Phillips head screw that holds the black rib...

Страница 12: ...ace by a bracket with 3 thumb screws Access to the push button assembly is located behind a cover on the underside of the visor To remove the push button assembly 1 Remove the 2 Phillips head screws t...

Страница 13: ...t Receptacles The 2 light receptacles are recessed in the light shield and are located on the underside of the canopy Each receptacle consists of a bulb socket and glass cover WARNING Before replacing...

Страница 14: ...et the upper duct section fall into the lower duct section Damage to the canopy can occur 2 Remove the two Phillips head screws one on each side that attach the upper section of the duct cover to the...

Страница 15: ...g the resistance between the two in terminals black and brown wires Resistance should be greater than 1M PTC Board The PTC board provides protection for the lighting circuit during momentary power sur...

Страница 16: ...s follows Insert screwdriver in the center of the space between the plug and connector receptacle on the PCB Push down on the screwdriver handle pivot blade about 5 degrees and pull out the plug at th...

Страница 17: ...Remove the duct cover See Duct Cover 5 Remove the power supply housing cover See Power Supply Housing 6 Remove the 4 Phillips head screws that hold the lower electrical component cover in place Remov...

Страница 18: ...to the fan power cable Insert the fan wiring through the power supply housing wire entry inlet 12 Grasp the fan motor assembly from the bottom Remove the 4 Phillips head screws that hold the fan motor...

Страница 19: ...MOTOR NO CHECK IF 120V AC IS PRESENT AT MOTOR TERMINAL BLOCK IN LEFT BLACK BOX NO YES ORDER MOTOR INSPECT PCB IN BLACKBOX NOTE 1 HOOD OK NO DONE ORDER INSTALL ENTRY DISPLAY ASSEMBLY CONTROL PCBS NO LI...

Страница 20: ...uctors Speed Test Wires Wires Jumped Resistance ohms 5 at 68 F 20 C 1 red black blue orange 20 6 2 red black white orange 14 4 3 red white white orange 7 6 BOOST red black black orange 7 6 MOTOR TEST...

Страница 21: ...ing Diagrams 42 0 42 3 2 2 2 7 2 7 2 7 2 7 2 7 2 7 6 6 6 2 2 54 7 4 7 4 5 5 2 3 4 42 5 5 5 7 4 7 4 2 5 2 2 7 7 4 4 2 4 2 2 93 2 02 33 2 2 5 4 7 6 4 0 7 2 3500 9 4 2 0 4 23 0 0 0 0 2 5 2 2 7 3 4 6 M 6...

Страница 22: ...tes do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may...

Отзывы: