ZV36TSFSS – GE Monogram 36" Stainless Steel Professional Hood

Specification Revised 3/03

Optional Duct Cover Accessories

Decorative duct covers are available in 6" and 12" heights. Duct covers may be
stacked, in various combinations, to conceal the ductwork running from the
top of the hood to the ceiling.

• Before you begin, you should determine the installation height of the

hood and order the correct size duct cover. The duct covers should be
ordered at the same time as the vent hood and be on site before 
installation. Order the duct cover corresponding to your model.

6" Duct Cover

12" Duct Cover

6" Duct Covers
Hood Model

6" Duct Cover

Dimensions

ZV48T, ZV48S

ZX48DC6

6"H x 19-11/16"W x 11-7/8"D 

ZV36T, ZV36S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC6

6"H x 15-3/4"W x 11-7/8"D

12" Duct Covers
Hood Model

12" Duct Cover

Dimensions

ZV48T, ZV48S

ZX48DC12

12"H x 19-11/16"W x 11-7/8"D 

ZV36T, ZV36S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

ZV30T, ZV30S

ZX36DC12

12"H x 15-3/4"W x 11-7/8"D

For answers to your Monogram,

® 

GE Profile

or 

GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center

®

service, 800.626.2000.

R

Listed by
Underwriters
Laboratories

Advanced Planning

Ductwork Planning

• These vent hoods are equipped for 10" round ductwork. In most instances

they may be transitioned to 8" round.

• This hood may be vented vertically through upper cabinets, soffit or ceiling.

A duct transition piece is supplied for vertical exhaust. Use locally supplied
elbows to vent horizontally through the rear wall.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For satisfactory 

performance, duct run should not exceed 150 ft. equivalent length for 
any duct configurations.

• Refer to “Duct Fittings” chart to compute the maximum permissible

length for duct runs to the outdoors.

• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior opening. Order

the wall or roof cap and any transition needed in advance.

Wall Framing for Adequate Support

• These vent hoods are heavy. Adequate structural support must be provided.

Hoods must be secured to vertical studs in the wall.

• It is strongly recommended that the vent hood with duct cover be on site

before final framing and wall finishing. This will also help to accurately
locate the ductwork and electrical service.

Decorative Duct Covers:

Decorative duct covers, 6" and 12" high, are available to fit all models. The
duct cover conceals the ductwork running from the top of the hood to the
ceiling or soffit. Stack one or more duct covers over the top of the hood 
to reach your ceiling height.

POWER SUPPLY

IMPORTANT – (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE

PROPERLY GROUNDED.

Remove house fuse or open circuit breaker before beginning installation.

Do not use an extension cord or adapter plug with this appliance. Follow
national electrical codes or prevailing local codes and ordinances

.

Electric supply

These vent hoods must be supplied with 120V, 60Hz, and connected to an
individual, properly grounded branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above requirements, call a

licensed electrician before proceeding.

• Route house wiring as close to the installation location as possible on the

back wall or ceiling.

• Connect the wiring to the house wiring in accordance with local codes.

Grounding instructions

The grounding conductor must be connected to a ground metal, permanent
wiring system, or an equipment-grounded terminal or lead on the hood.

WARNING:

The improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a qualified 
electrician or service representative if you are in doubt whether the appliance
is properly grounded.

Содержание MONOGRAM ZV36TSFSS

Страница 1: ...oods may be installed 24 min above a gas or electric drop in style cooktop Always observe the 30 to 36 clearance when installed over any professional style cooktop or range Note Clearances may vary due to type of cooking product and local codes Check with local inspectors to be sure standard is applicable Soffit Installation SOFFIT 30 MIN 36 MAX In this installation the ductwork running from the t...

Страница 2: ...length for duct runs to the outdoors Use metal ductwork only Install a wall cap or roof cap with damper at the exterior opening Order the wall or roof cap and any transition needed in advance Wall Framing for Adequate Support These vent hoods are heavy Adequate structural support must be provided Hoods must be secured to vertical studs in the wall It is strongly recommended that the vent hood with...

Страница 3: ...al service Read these examples carefully to determine the need for one or more 6 or 12 duct covers A Countertop to ceiling height B Gap at the top of the hood to the ceiling C Hood installation height Plus 18 hood height NOTE Dia C should be between 48 and 54 for a 30 to 36 installation height Raise or lower the hood installation height to allow use of one or more 6 and 12 duct covers A B C Ceilin...

Страница 4: ...teel Professional Hood Features and Benefits 640 CFM Vertical Exhaust Variable Speed Fan Control 2 Halogen Lamps with 4 Lighting Levels Infrared Warming Lamp Utensil Rod Removable Grease Trays Removable Baffle Stainless Steel Filters Model ZV36TSFSS Stainless steel ...

Отзывы: