GE Monogram ZTS90DSSNSS Скачать руководство пользователя страница 2

2 A

  CUTOUT FOR SINGLE OVENS IN WALL CABINET

NOTE:

 If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick, 

shim both sides equally to establish the cutout width.

These ovens 

are not 

approved for 

installations that 

stack one single 

wall oven above 

another single 

wall oven.

Cutout – 

observe all 

dimensions and 

requirements.

Cutout – 

observe all 

dimensions and 

requirements.

2” (5.1 cm) Min.

30.5” (77.5 cm)  

30” models

27” (68.58 cm)  

27” models

Center Line

Center Line

Side-by-Side Installations

Install two ovens in separate cutouts.

2 B

  

CUTOUT FOR SINGLE OVENS – UNDER COUNTER

NOTE: 

These ovens are only approved to be installed under the specific models as labeled on 

the unit. 

NOTE: 

One cooktop may be centered over either 

oven in the side-by-side installation.

Cutout – observe 

all dimensions and 

requirements.

2” (5.1 cm) Min.

30.5” (77.5 cm) 30” models

27” (68.58 cm) 27” models

Center Line

Center Line

Side-by-Side Installations

Install two ovens in separate cutouts.

Cooktop

Cutout – observe 

all dimensions and 

requirements.

H

B

F

G

C

D

A

E

Junction 

Box 

Location 

(junction 

box may 

be located 

in adjacent 

cabinet)

22” (55.9 

cm) Min. 

to Bottom 

of Junction 

Box

Cutout Depth  

23-1/2”  

(59.7 cm) Min.

Recommended 

Cutout Location 

from Floor  

32-1/2” (82.6 cm)

Opening 

Between Inside 

Walls Must be 

at Least 28-1/2” 

(72.4 cm) Wide

NOTE: 

Allow 

1/4” (0.64 cm) 
clearances from 
side edges of 
oven door.

Continue to Section 4.

Dimension

Dimension Description

27” Single Oven

30” Single Oven

A

Cabinet Width

25” (63.5 cm) min.

25

1

»

4

” (64.1 cm) max.

28

1

»

2

” (72.4 cm) min.

28

5

»

8

” (72.7 cm) max.

B

Cutout Height

27

5

»

8

” (70.2 cm) min.

28

1

»

8

” (71.4 cm) max.

27

1

»

4

” (69.2 cm) min.

27

5

»

16

” (69.4 cm) max.

C

Clearance from cutout - top*

1” (2.5 cm)

1” (2.5 cm)

(1

1

»

4

” (3.2 cm) for 

PT9050

ZET1S and ZET1P)

D

Clearance from cutout - bottom*

1” (2.5 cm)

1

1

»

4

” (3.2 cm)

E

Clearance from cutout - side edges*

1” (2.5 cm)

11

»

16

” (1.75 cm)

F

Junction Box Location

8

3

»

4

” (22.2 cm) max. 

right side only

9

1

»

2

” (24.1 cm) max. 

right side only

*  Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.

Dimension

Dimension Description

27” Single Oven

30” Single Oven

A

Cabinet Width

27” (68.6 cm)

30” (76.2 cm)

B

Cutout Width

25” (63.5 cm) min.

25

1

»

4

” (64.1 cm) max.

28

1

»

2

” (72.4 cm) min.

28

5

»

8

” (72.7 cm) max.

C

Cutout Height

27

5

»

8

” (70.2 cm) min.

28

1

»

8

” (71.4 cm) max.

27

1

»

4

” (69.2 cm) min.

27

5

»

16

” (69.4 cm) max.

D

Clearance from cutout - 

side edges*

1” (2.5 cm)

11

»

16

” (1.75 cm) 

E

Clearance to Adjacent 

Corners, Drawers, Walls, 

etc., When Door Is Open

23” (50.8 cm) min.

23” (53.3 cm) min.

F

Clearance from cutout - 

top*

1” (2.5 cm) min.

1” (2.5 cm) min. 

(1

1

»

4

” (3.2 cm) for PT9050, 

ZET1S and ZET1P)

G

Clearance from cutout - 

bottom*

1” (2.5 cm) min.

1

1

»

4

” (3.2 cm)

H

Junction Box Location 

8

3

»

4

” (22.2 cm) max. 

right side only

9

1

»

2

” (24.1 cm) max. 

right side only

*  Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.

IMPORTANT:

 Maintain 

a minimum distance 
of 31-1/4” from the 
top surface of the 
countertop to the 
wall oven platform to 
ensure that the cooktop 
and wall oven do not 
interfere with each other 
(see picture).

31-1/4” min.

(79.4 cm)

 

 

 

 

 

 

SIDE VIEW

Cooktop

 

Wall Oven 

2-1/2” min. (6.4cm)  

Содержание Monogram ZTS90DSSNSS

Страница 1: ...remove plastic on trims and panel all tape around the oven and any shipping screws securing the oven to the base pad Open oven door and remove literature pack and oven racks Remove the bottom trim fr...

Страница 2: ...0 Single Oven A Cabinet Width 25 63 5 cm min 251 4 64 1 cm max 281 2 72 4 cm min 285 8 72 7 cm max B Cutout Height 275 8 70 2 cm min 281 8 71 4 cm max 271 4 69 2 cm min 275 16 69 4 cm max C Clearance...

Страница 3: ...11 4 3 2 cm 11 4 3 2 cm H Junction Box Location 83 4 22 2 cm max right side only 91 2 24 1 cm max right side only 91 2 24 1 cm max right side only J Height to Bottom of Junction Box 44 111 8 cm 47 11...

Страница 4: ...ment 2 5 1 cm Min Per Warming Drawer Requirement Continue to Section 3 for Double Wall Oven with Pedestal Otherwise continue to Section 4 3 A DETERMINING WHEN TO USE THE PEDESTAL 30 DOUBLE OVENS ONLY...

Страница 5: ...WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation WARNING Improper connection of aluminum house wiring to copper leads can result in an electrical hazard...

Страница 6: ...and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts C Install proper strain relief clamp D Install junction box cover Ground and neutral wires white...

Страница 7: ...oven B Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against outside edges C As you slide the oven back pull the string so that the...

Страница 8: ...see Section 11 Ensure that air duct opening at bottom of unit is free of obstructions Check that oven rack guides if applicable are installed correctly and oven racks function smoothly If applicable...

Страница 9: ...ebordes y panel toda la cinta que cubre el horno y los tornillos de env o que fijan el horno a la almohadilla base Abra la puerta del horno y quite el material informativo y las bandejas del horno Qui...

Страница 10: ...binete 25 63 5 cm m n 251 4 64 1 cm m x 281 2 72 4 cm m n 285 8 72 7 cm m x B Altura de la abertura 275 8 70 2 cm m n 281 8 71 4 cm m x 271 4 69 2 cm m n 275 16 69 4 cm m x C Espacio desde la abertura...

Страница 11: ...tura parte superior 1 2 5 cm min 1 2 5 cm min 11 4 3 2 cm para PT9550 ZET2S y ZET2P 1 2 5 cm min 11 4 3 2 cm para PT9550 ZET2S y ZET2P G Espacio desde la abertura parte inferior 1 2 5 cm min 11 4 3 2...

Страница 12: ...l gabinete se encuentra en la condici n de ancho m ximo repare los tacos de madera como se muestra en la ilustraci n 3 B INSTALACI N DEL RIEL CON PEDESTAL 30 HORNOS DOBLES NICAMENTE A Posicione los ri...

Страница 13: ...este aparato ADVERTENCIA Para prevenir una descarga el ctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n ADVERTENCIA Una conexi n inadecuada de cableado dom s...

Страница 14: ...kg Conecte el conducto flexible a la caja de conexiones el ctrica como se indica abajo Posicione el conducto de modo tal que se apoye detr s de la unidad en un c rculo natural cuando el horno sea inst...

Страница 15: ...locales A Evite que el conductor neutro blanco quede enredado con cualquier otro cable De ser necesario corte el conductor neutro blanco y luego vuelva a pelar el mismo a fin de exponer la longitud ad...

Страница 16: ...bstrucciones Controle que las gu as de los estantes del horno si corresponde est n instaladas de forma correcta y que los estantes del horno funcionen de forma fluida Si corresponde instale las manija...

Отзывы: