36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Case Depth
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Style Models
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The cutout depth must be 24
”
7KHUHIULJHUDWRUZLOOSURMHFWIRUZDUGVOLJKWO\EH\RQG
adjacent cabinetry, depending on your installation.
Allow minimum 1/8” air gap between case back & wall.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 24
”
LQVWDOODWLRQGHSWKVKRZQ7KHWRSFDVHWULP
overlaps the bottom of the soffit.
Additional Specifications
$YROW+]RUDPSSRZHUVXSSO\LVUHTXLUHG
An individual properly grounded branch circuit or circuit
breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
:DWHUOLQHFDQHQWHUWKHRSHQLQJWKURXJKWKHIORRU
RUEDFNZDOO5RXWH*(6PDUW&RQQHFW
™
kit or 1/4
”
O.D.
copper tubing between the cold water line and the
ZDWHUFRQQHFWLRQORFDWLRQ7KHWXELQJVKRXOGEH
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in the
water line is required.
DIMENSIONS AND CLEARANCES
6KLSSLQJKHLJKW7KH
refrigerator can be
adjusted to fit into a
cutout that is 83-1/2
”
min. to 84-1/2
”
max.
height. Note that the top
case trim at the front is
1/2
”
higher and will
overlap upper cabinetry
RUVRIILW8VHOHYHOLQJ
legs and wheels for a
maximum 1
”
height
adjustment.
Product Clearances
7KHVHUHIULJHUDWRUVDUHHTXLSSHGZLWKDSRVLWLRQGRRU
VWRS7KHIDFWRU\VHWGRRUVZLQJFDQEHDGMXVWHGWR
90° if clearance to adjacent cabinets or walls is restricted.
3
6"
Wall View
Electrical
Area
84-1/2" max
83-1/2" min
Finished
Opening
75" From
Floor to Bottom
of Electrical Area
10"
24" Cutout Depth
35-1/2"
Finished Width
2-5/16"
5"
10"
10"
3-1/2"
3-1/2"
5"
3-1/2"
Water Supply
ZUG2, ZUGSS2 Unified Grille Panel Kit
,I\RXDUHLQVWDOOLQJWZRUHIULJHUDWRUVVLGHE\VLGH
the installation space must be 71-1/2
”
wide.
Note:
Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width.
7KHZDWHUDQGHOHFWULFDOORFDWLRQVIRUHDFKSURGXFW
must be located as shown.
$VH]RUDPSSRZHUVXSSO\LV
recommended for each product.
7KHILQLVKHG
cutout width
must be
35-1/2
”
.
Allow 25
”
minimum clearance for a full 130° door
swing. Allow 15
”
for pan removal.
For a 90° door swing, allow 4
”
min. clearance to a wall,
for framed and stainless steel models. Allow 5
”
min.
clearance for professional style models. If the 90° door
stop position is used, pan access is maintained, but pan
removal is restricted.
See illustrations pages 4 and 5 to determine door swing
interaction with adjacent cabinets or countertops.