4
PRODUCT DIMENSIONS AND CLEARANCES FOR 48” MODELS
Design Information
27-1/2” to
Front of
Bullnose
8-1/2”
Height
22-3/4” Min.
2-1/2”
8”
7/8”
Universal Utility Locations
2”
17”
16”
Locate gas
inlet on back
wall or on
floor 2” from
back wall.
12” Minimum
Each Side
46-1/4”
48” Min. to
Combustibles
12” Minimum to
Combustibles or 0”
to non-combustible
material above the
cooking surface
0”
Clearance
* The opening between a 4” high
backsplash must be 48” to allow the
rangetop to slide back against the wall.
13” Max.
18” Min.
48” Minimum
to Combustibles
12” Minimum to
Adjacent Wall
47-7/8
”
Width
WARNING:
Installations without a hood
require 48” minimum to combustibles
above the rangetop. A custom hood
installation with exposed horizontal
combustible surfaces must have
an Auto-On feature. Refer to hood
installation instructions for specific
hood clearances.
The surface of the entire back wall
above the countertop and below
the hood must be covered with
a non-combustible material such
as metal, ceramic tile, brick, marble
or other stone.
*48”
Non-
combustible
material
48”
ADDITIONAL CLEARANCES:
Allow 12” minimum clearance to an
adjacent wall on each side.
Working areas adjacent to the rangetop
should have 18” minimum clearance
between countertop and the bottom of
the wall cabinet.
For island installation, maintain 2-1/2
in. minimum from cutout to back edge
of countertop and 3 in. minimum from
cutout to side edges of countertop (see
top view).
Back
3” Min.
Island
Cutout
Top View
3” Min.
2-1/2” Min.