– 42 –
Surface Burner Valve and Switch
Each surface burner valve utilizes a switch. When a
burner knob is turned to the ON position, the valve
switch closes and activates the spark module and
the LED light. Each surface burner valve switch is
installed on the front of the burner valve body. The
switches are all wired to a single harness and are
replaced as one assembly. It is necessary to remove
the valve to access the switch.
Note:
The following describes the procedure to
remove a single burner valve and switch. The
procedure to remove the remaining valves and
switches is identical.
To remove the surface burner valve and switch:
Remove the burner pan located over the valve
1.
and switch to be replaced. (See
Surface Burner
Pan
.)
Remove the heat barrier by lifting it out of the
2.
burner box.
Remove the 7/16-in. nut and the 9/16-in. nut
3.
from the valve.
4. Remove the Phillips-head screw and the
indicator light assembly from the valve bracket.
(See
Indicator Light Assembly
.)
5. Slide down and remove the wiring retainer clip
from the frame.
6. Using a ratchet wrench, remove the 1/4-in.
hex-head screw that attaches the valve to the
manifold.
7. Maneuver the valve below the bracket and slide
the valve switch from the valve stem.
Caution:
Ensure the valve seal and the screw seal
are in place BEFORE installing the valve.
Screw Seal
Valve Seal
Clip
Valve Switch
Valve Stem
Note:
The bottom of each switch is molded to
conform to the front of the valve for a locked-in
fi
t.
For proper igniter operation, each switch must be
locked-in to the top of the valve. When installing
the switch, align each switch to the valve stem and
body. Push the switch down
fi
rmly until an audible
"snap" is detected.