background image

For answers to your Monogram,

® 

GE Profile

 or 

GE

®

 appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

130564

Specification Created 12/10

Listed by 

Underwriters 

Laboratories

ZGP484NGRSS (Natural Gas)

ZGP484LGRSS (Liquid Propane)

GE Monogram

® 

48" All-Gas Professional Range with 4 Burners, Grill  

and Griddle

Dimensions and Installation Information (in inches) 

Electrical Requirements

Ranges must be hooked up to a 120V, 60Hz properly 
grounded dedicated circuit protected by a 15-amp circuit 
breaker or time-delay fuse.

Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. The following 
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 48"-wide range backsplash

ZX12B48PSS–12" backsplash

ZXADJB48PSS– 30"-36" adjustable-height backsplash with 

warming shelf

Side View with a Backsplash

Locate gas and  
electric as shown

Universal Utility Locations

8”

23”

48”

6”

2”

3”

6-1/2”

Gas/

Electric

Gas/

Electric

10-1/2”

1-1/2”

12”

28-1/4” to

Beveled 

Edge of Control

Panel Bullnose

27-1/2” to

Beveled Edge

- Maximum

Adjacent

Cabinet Depth

for

Flush

Installation

13/16”

30-36”

3-3/16”

Control Panel

Depth

28-1/4”

to Front of

Door

48-1/4”

with Oven Door

Open

31-1/16”

to Front of

Handle

35-1/4”

to

36-3/4”

7” Control

Panel Height

28-7/8”

to Front

Edge

Optional

Backsplash

Accessories

Gas Supply

•  The natural gas models are designed to 

operate at 5" water column pressure. 
For proper operation, the pressure of 
the natural gas supplied to the regulator 
must be between 7" and 13" water 
column.

•  The LP models are designed to operate 

at 10" water column pressure. For 
proper operation, the pressure of the LP 
gas supplied to the regulator must be 
between 11" and 13" water column.

Universal Utility Locations