Installation
Digital Radiant Cooktop
7
4
Connect
Electrical
Step
Verify that power is turned off at the source
Connect cooktop flexible power cable to
junction box:
• Use a proper-sized flexible conduit
connector, securely attached.
• Do not shorten power cable; it should hang
in a natural loop when installed.
When connecting to a 4-conductor branch
circuit:
• Connect red lead to branch circuit
red lead.
• Connect cooktop black lead to branch
circuit black lead.
• Connect cooktop ground conductor
(green) to branch circuit ground
conductor (bare or green).
When connecting to a 3-conductor branch
circuit:
• Connect cooktop red lead to branch circuit
red lead.
• Connect cooktop black lead to branch
circuit black lead.
• Connect cooktop bare copper or green
conductor to branch circuit ground lead
(white or gray).
If house wiring is not 2-wire
with a ground wire, a
ground must be provided
by the installer.
When house wiring is
aluminum, be sure to use
U.L. approved anti-oxidant
compound and aluminum-
to-copper connectors.
WARNING