GE Monogram ZET958 Скачать руководство пользователя страница 2

10

CUTOUT

HEIGHT

51 13/16" MIN.

51 15/16" MAX.

5"

CUTOUT

WIDTH

28 1/2" MIN.

28 5/8" MAX.

47" TO

BOTTOM OF 

JUNCTION BOX

JUNCTION BOX

LOCATION

ALLOW 11/16"

FOR OVERLAP

OF THE OVEN

OVER SIDE EDGES

OF CUTOUT

THE OPENING 

BETWEEN INSIDE

 WALLS MUST

BE AT LEAST 

28 1/2"WIDE

ALLOW 1" FOR 

OVERLAP 

ON OVEN TOP 

AND BOTTOM 

OF CUTOUT

21"

ALLOW A MINIMUM OF 21"

FOR CLEARANCE TO

ADJACENT CORNERS, 

DRAWERS, WALLS ETC. 

WHEN THE DOOR

IS OPENED.

30"

CABINET

WIDTH

RECOMMENDED

CUTOUT LOCATION

12" FROM THE FLOOR

Installation Instructions

Cabinet Width

30

” 

(76.2 cm)

Recommended
Cutout Location
from Floor

12

” 

(30.5 cm)

Cutout Depth

23 1/2

” 

(59.7 cm) Min.

Cutout Width

28 1/2

” 

(72.4 cm) Min.

28 5/8

” 

(72.7 cm) Max.

Cutout Height

51 13/16

” 

(131.6 cm) Min.

51 15/16

” 

(131.9 cm) Max.

If the cabinet does not have a solid bottom,
two braces or runners must be installed
level with the bottom of the cutout to
support the weight of the oven. For
double ovens, the runners and braces
must support 275 lbs (124 Kg).

Cutout for 30

 

(76.2 cm)

 

Double Built-In Ovens only

For JTP35, JTP55, JTP75, PT956, PT960, ZET958 models only.

NOTE: If the cabinet does not
have a front frame and the sides
are less than 3/4

 (1.9 cm) thick,

shim both sides equally to
establish the cutout width.

NOTE: If marks, blemishes or the
cutout opening are visible above the
installed oven, it may be necessary to
add wood shims under the runners and
front trim until the marks or opening
are covered.

9 1/2

(24.1 cm)

Max.

Allow 11/16

(1.75 cm) for
overlap of oven
over side edges
of cutout

30

(76.2 cm)

Cabinet

Width

21

” (53.3 cm)

Junction Box
Location
(junction box
may be
located in
adjacent
cabinet)

Allow a minimum
of 21

 (53.3 cm) for

clearance to adjacent
corners, drawers,
walls, etc. when
door is open

Allow 1

 (2.5 cm)

minimum for
overlap of oven
top and 1

1

4

(3.2 cm) overlap
of oven bottom
of cutout

Recommended
cutout location
from floor 12

” 

(30.5 cm)

47

 (119.4 cm)

Min.

to Bottom of

Junction Box

A

C

L

2" x  4" or
EQUIVALENT
RUNNERS

21 5/8"

OVER CENTERLINE

OF CABINET

2

 x 4

(5 cm  x 10 cm)
or equivalent
runners level
with bottom
of cutout

21 5/8

(54.9 cm) Over

Centerline
of Cabinet

Opening
Between
Inside Walls
Must Be At
Least 28 1/2

(72.4 cm) Wide

Cutout

Width

28 1/2

 (72.4 cm)

Min.

28 5/8

 (72.7 cm)

Max.

Cutout
Height
51 13/16

 131.6 cm)

Min.
51 15/16

 (131.9 cm)

Max

.

Suitable
Bracing
to Support
Runners

Содержание Monogram ZET958

Страница 1: ...tterymarch Park Quincy MA 02269 Effective January 1 1996 the National Electrical Code requires that new but not existing construction utilize a four conductor connection to an electric oven When installing an electric oven in new construction a mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor follow the instructions in the section on NE...

Страница 2: ...8 models only NOTE If the cabinet does not have a front frame and the sides are less than 3 4 1 9 cm thick shim both sides equally to establish the cutout width NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered 9 1 2 24 1 cm Max Allow 11 16 1 75 cm for over...

Страница 3: ... the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire Turn off the circuit breaker or remove fuses to the oven branch circuit With the oven supported on a table or platform in front of the cabinet opening connect the flexible conduit to the electrical junction box as shown below Position the conduit in such a manner that it will lie on top of the...

Страница 4: ... construction or When installing in a mobile home or When installing in a recreational vehicle or When local codes do not permit grounding through neutral a Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor b Attach the appliance grounding lead green or bare copper in accordance with local codes If the residence grounding conductor i...

Страница 5: ...efore the oven is slid into place This will keep the conduit from falling behind the oven b Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against outside edges c As you slide the oven back pull the string so that the conduit will lie on top of the oven in a natural loop d When you are sure the conduit is out of the way slide the ...

Отзывы: