Panic button
You may choose to install an optional panic button, typically within reach of the driver.
There are two versions of the panic button: one with a key reset and one without (
).
Figure 53. Panic buttons
To install the panic button, do the following:
1. Using the panic button as a template, mark the location of the mounting holes.
2. Using a 3/16 in. (5 mm) drill bit, drill the mounting holes.
3. Using a 3/4 in. (20 mm) drill bit, drill a hole for the panic button’s wiring.
4. Splice (solder wires and heat shrink exposed wire) a six-conductor 18 AWG cable to
the panic button’s wiring.
Note:
The panic button with key reset has six wires, and the panic button without key reset has
only five. The NC and common wires are both yellow and are interchangeable.
5. Route the cable to the DVR. See
and connect the cable to the J1 and J13
back box connectors as follows:
•
Connect the yellow NC and common wires to J13, terminals 1 and 11.
•
Connect the gray positive wire to J13, terminal 11 or any other available 12 V
terminal.
•
Connect the green normal wire to J1, terminal 7.
•
Connect the red check wire to J1, terminal 8.
Panic button with key reset
Panic button
Содержание MobileView 4
Страница 1: ...MobileView g MobileView 4 Installation Manual ...
Страница 16: ...MobileView 4 Installation Manual 6 ...
Страница 44: ...MobileView 4 Installation Manual 34 Figure 29 Commit application ...
Страница 47: ...Chapter 4 DVR configuration 37 Figure 32 Vehicle setup ...
Страница 59: ...Chapter 4 DVR configuration 49 Figure 38 Alarm events ...
Страница 68: ...MobileView 4 Installation Manual 58 ...
Страница 94: ...MobileView 4 Installation Manual 84 ...
Страница 104: ...MobileView 4 Installation Manual 94 ...