System settings
The
Shutdown dwell time
) sets the length of time that the recorder will
continue to operate and record after the
ignition
or
engine run
signals are removed.
This setting only applies to recorders with the shutdown dwell feature enabled. Setting the
value to 0 deactivates the feature. For the setting shown, the DVR will continue recording
for 10 seconds after the
ignition
or
engine run
signals are removed.
Figure 41. Shutdown dwell time
Camera settings
When you enter the number of cameras into the system that are physically attached to a
recorder through the
Number of cameras installed
field (
), the recording system
will periodically check to ensure that pictures are being received and recorded for all
expected cameras.
Figure 42. Camera settings