18
MDS TransNEXT Technical Manual
MDS 05-7280A01, Rev. A
NOTE
GE MDS part number 73-2434A25 provides a custom RJ45 to DB9 Adapter for use with the
TransNEXT and other GE MDS products. The chart below provides details for connections
made using this adapter.
WIRING CHART
RJ-45 PIN
FUNCTION
DB9 PIN
1
DSR
6
2
DCD
1
3
DTR
4
4
GND
5
5
RXD
2
6
TXD
3
7
CTS
8
8
RTS
7
LED / Button Panel
—The LEDs on the top of the unit provide visual indications of device status. The
push button (appearing like a thin white circle) is used for special functions like controlling the optional
E-ink display screen.
Figure 2-6. LED Indicators & Push Button