TROUBLESHOOTING
For proper operation, all radios in the network must meet these basic
requirements:
• Adequate and stable primary power.
• Secure connections (RF, data and power)
• An efficient and properly aligned antenna system with a
received signal strength of at least –90 dBm. (It is possible for a
system to operate with weaker signals, but reliability will be
degraded.)
• Proper programming of the transceiver’s operating parameters
(see
SOFTWARE COMMAND SUMMARY on Page 7
).
OWM [XXX...]
Set or display the owner’s message.
OWN [XXX...]
Set or display the owner’s name.
PORT [RS232, RS485]
Selects signaling standard to be used on
DATA port.
PWR [20–37]
Set or display the transmit power setting.
RSSI
Display the Received Signal Strength
Indication.
RTU [ON/OFF/0-80]
Re-enables or disables the radio’s internal
RTU simulator and sets the RTU address.
RX [xxx.xxxx]
Set or display receiver frequency.
SER
Display the radio serial number.
SPECTRUM
[xxx.xx x.x]
Display internal spectrum analyzer, where
x
characters denote center frequency and
span frequency in MHz, respectively.
SREV
Display the Software Revision Level.
STAT
Display radio status and alarms.
TEMP
Display the internal temperature of the radio
in degrees C.
TX [xxx.xxxx]
Set or display the transmit frequency.
UNIT [10000...65000]
Set or display the transceiver’s unit address.
Table 2. Command Summary
(Cont’d)
Command Name
Function