15
Door Panel
The door panel covers the main control board,
detergent cup, vent, wax motor, louver, and
door-interlock switch. The outer door panel is
held in place by 14 screws (7 Phillips head
screws per side)
NOTE: Ribbon cable(s) connect the keypad
membrane (2-digit display on some models)
to the control circuit board. Due to the ribbon
length, care much be taken when removing
the door panel to ensure that the ribbon
cable(s) are not damaged.
Membrane Keypad
The door panel must be removed to access
the membrane keypad (see Door Panel).
When removing the membrane keypad, peel
the keypad from right to left.
On models with an LED display, the display is
held in place with a plastic clip.
NOTE: When replacing the keypad membrane,
always run the Service Mode to calibrate the
keypad membrane to the control board.
Control Module
The door panel must be removed to access
the control module (see Door Panel). The main
control is considered a “smart” control,
capable of learning the water temperature
and turbidity characteristics of the home.
It is normal if the cycle times vary over a
period of time from the factory default
settings due to temperature and water
quality.
The control module is held in place by two
screws that secures the module to the right
side of the inner door panel.
Содержание Mabe GLD9312
Страница 20: ...20 Schematic Vent Wax motor...