background image

4

6

Take the provided safety tether and loop one end

of the tether to existing rough-in kit.

7

Attach the other end of the safety tether to the

fixture using one of the three holes located on the 

fixture brackets. Feed the button stop and toggle 

through the hole and slide into the hole in the 

bracket. Allow the fixture to hang freely.

Feed button stop 

and toggle through 

hole in bracket

Safety 

tether

Button stop

Toggle

Assembled connector 

housing

Connect two 

quick connects

8

Connect the fixture assembly to the driver enclosure

assembly with the supplied quick connects and 

assemble the connector housing when finished.

9

Cut cable tie on fixture so that the fixture is ready

to be installed.

Final 

installation 

position for 

springs

Push fixture through the hole in the ceiling. This will 

engage the protruding arms, thus, releasing the 

springs. The springs will draw the fixture up into the 

ceiling and hold it there tightly.

11

 CAUTION

RISK OF PERSONAL INJURY - 

Operators shall ensure no 

appendages are in the path of the torsion springs 

as they are a pinch hazard when released. The 

springs will release when the arm is flexed downward. 

Be cautious that no body part is in the path of the 

spring when released.

Position fixture so 

rough-in kit

support arms do not 

interfere with springs

Position the fixture below the ceiling so that two of the 

three springs are on each side of the rough-in kit support 

arms. This is necessary in order to make sure that when 

the springs release, the rough-in kit support arms don’t 

interfere and prevent the springs from making contact 

with the top of the ceiling for proper support.
NOTE: 

Ensure the fixture is positioned properly before 

installing in the ceiling so the springs don’t interfere with the 

support arms.

10

Содержание Lumination LRC Series

Страница 1: ...es continues L installation de cet ensemble de réaménagement nécessite une personne familiarisée avec la construction et le fonctionnement du système électrique du luminaire et avec les risques encourus Si non qualifié ne tentez pas l installation Contactez un électricien qualifié Pour prévenir les dommages ou l abrasion de fils électriques ne pas exposer les fils aux arêtes de pièce de tôlerie ou...

Страница 2: ...3 8 7 9 7 C Height from Bottom of Ceiling inches 4000lm 6 65 8 1 9 35 10 45 D Max Applicable Hole Diameter inches w Goof Ring 8 5 10 2 12 1 NA Minimum Spacing Requirements for all Fixture Configurations Center to center of adjacent luminaires 24 Top of Luminaire to overhead building member 3 Luminaire center to side building member 12 Reflector Orientation When Mounting LRCXXXXXXWWXXXXXXXXXX SKUs ...

Страница 3: ...onents such as lamp sockets ballasts etc while retaining existing rough in kit components SHUT OFF POWER to the lighting system Remove Remove Ceiling Quick connector AC Input Leads Green Ground White Neutral Black Hot Driver enclosure Junction box 5 Connect flex cable end with input leads to existing junction box Connect the black white and green wires of the input leads to the black white and gre...

Страница 4: ...n the ceiling This will engage the protruding arms thus releasing the springs The springs will draw the fixture up into the ceiling and hold it there tightly 11 CAUTION RISK OF PERSONAL INJURY Operators shall ensure no appendages are in the path of the torsion springs as they are a pinch hazard when released The springs will release when the arm is flexed downward Be cautious that no body part is ...

Страница 5: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Limited 5 Year Warranty DRIVER TP...

Отзывы: