background image

Installation Guide

IND544 | A-1026317

BEFORE YOU BEGIN 

Read these instructions completely and carefully.

  

WARNING / AVERTISSEMENT

RISK OF ELECTRIC SHOCK

• Turn power off before inspection, installation or removal.

• Properly ground electrical enclosure.

RISK OF FIRE

• Follow all NEC and local codes.

• Use only UL approved wire for input / output connections. Minimum 

   size 18 AWG or 14 AWG for continuous runs.

Prepare Electrical Wiring

Electrical Requirements

• The LED driver must be uspplied with 120V to  

   277V for LDXBxx0xxxxxxx fixtures and 347V for 

   LDXBxxDxxxxxxx fixtures. 50/60 Hz and connected 

   to an individual properly grounded branch circuit, 

   protected by a 20 ampere circuit breaker. Use min. 

   90

o

C supply conductor.

Grounding Instructions

• The grounding and bonding of the overall system 

   shall be done in accordance to local electric code of 

   the country where the luminire is installed.

RISQUES DE DÉCHARGES ÉLECTRIQUES

• Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.

• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.

RISQUES D’INCENDIE

• Respectez tous les codes NEC et codes locaux.

• N’utilisez que des fils approuvés par UL pour les entrées/sorties de connexion. Taille  

   minimum 18 AWGou 14 AWG pour les rangées continues.

Save These Instructions

Use only in the manner intended by the ma

nufacturer.

If you have any questions, contact the manufacturer.

Lumination

®

 LED Luminaire

LDXB Series

This device complies with Part 15 of the FCC Rules. Operation is subject 

tothe following two conditions: (1) This device may not cause harmful 

interference,and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

CAN ICE-005(A)/NMB-005(A)

Note: 

This equipment has been tested and found to comply with the 

limits for a Class Adigital device, pursuant to part 15 of the FCC Rules. 

These limits are  designed to provide reasonable protection against 

harmful interference when the equipment is operated in a commercial 

environment. This equipment  generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential area 

is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

Содержание Lumination LDXB Series

Страница 1: ...ctez tous les codes NEC et codes locaux N utilisez que des fils approuvés par UL pour les entrées sorties de connexion Taille minimum 18 AWGou 14 AWG pour les rangées continues Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Lumination LED Luminaire LDXB Series This device complies with Part 15 of the FCC Rules Operatio...

Страница 2: ...sh with ceiling and secure by tightening both adjustable mounting bracket wingnuts NOTE Refer to step 7 for trimless installation 4 Slide reflector into the fixture Verify reflector trim is flush with ceiling Repeat step 4 if trim is not flush For wall wash reflectors position reflector so that light is directed towards wall 5 Fixture Hole Size 4 in round fixture 5 in 126mm diameter hole 6 in roun...

Страница 3: ... set 7 Dust off any particles that may have adhered to the light module Slide the reflector into the fixture 8 Ensure that muddy frame is lined up with rig frame and secure it to the ceiling using fine thread 6 x 11 4 2 drywall screws not included Prior to plastering and painting insert the light reflector to ensure that reflector is fush with the ceiling Repeat step 4 for height adjustment if nee...

Страница 4: ...de the room 4 Remove reflector from fixture Save for future re installation 1 Turn off power 5 Disconnect DC connection 6 Reverse steps 1 6 using the replacement LED module 7 Open quick disconnect J box with flathead screwdriver Note Align both arrows before installing the light engine Once both arrows are aligned push the LED module and then rotate it clockwise to engage 3 clips ...

Страница 5: ...lip 3 Bring driver inside the room and remove connections with a pair of tweezers or a small screwdriver 4 Clip Driver Clip Driver Remove LED module by and pushing upward and then counterclockwise to disengage 3 clips 1 Turn off power and remove reflector 5 Re install replacement driver by reversing steps 1 4 ...

Страница 6: ... 3 Open quick disconnect J box with flathead screwdriver 4 Remove LED module by pushing up then counterclockwise to disengage 3 clips 1 Remove LED module by pushing up then turning counterclockwise to disengage 3 clips 5 Open door NOTE Some parts in the illustraition are hidden for clarity 6 Disconnect DC connection Continued on pg 7 ...

Страница 7: ...cement Pull out the extension tray NOTE Some parts in the illustraition are hidden for clarity 9 Bring all connections from the JBox to the downlight opening 7 Disconnect AC connections dimming and test button 8 10 Re install replacement tray by reversing steps 1 9 ...

Страница 8: ...y sharp edges and excessive strain on wiring For Options TQ and TS Connect the black line of the AC line to the black 120V 277V or 347V wire Connect the white neutral wires of the AC line to the white wires using the provided 18 12 AWG push in connectors Finally connect the green ground wire of the AC line to the green wire using the provided 18 12 AWG push in connector Leave the red wire unconnec...

Страница 9: ...9 Lumination LDXB Series Installation Guide ...

Страница 10: ...10 Lumination LDXB Series Installation Guide TS ...

Страница 11: ...eck circuit breaker Check that the color of the supply side wires match the color of the wires they are connected to Check that the LED driver connector is fully engaged to the LED light engine connector Check that the LED light engines are connected at the junction between the two luminaires Luminaire is dim Dimming wire connection shall be checked and if connection is not proper reconnect it If ...