![GE Lumination BL44 Series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/ge/lumination-bl44-series/lumination-bl44-series_installation-manual_128077003.webp)
Dimming line
(optional)
3
Optional:
If using a dimmer, connect black and red wires
of the dimming line to the D1 and D2 positions on the
terminal block.
2
1
Fasten mounting brackets over screws but do not
tighten them at this point. Note that bracket flaps have
to be aligned with the groove.
Slide two bracket mounting screws into housing groove
on each side (four screws per housing). If the screw head
cannot pass through end cover groove, remove end covers
and slide the screw head directly into the housing groove,
then re-install end covers.
Luminaire Installation
Follow diagram A for 0-10V or diagram B for DALI. Run wires from controller through a different knockout than the AC input wire.
At output side of LED Driver, make appropriate connections using twist-on wire connectors. Follow lighting controller installation
instructions.
BLU/WHT
BLK/WHT
YEL
GRY
VIO
VIO/WHT
LED Driv
er
To 0-10V
Dimmer
0-10V -
0-10V +
BLU/WHT
BLK/WHT
YEL
GRY
VIO
VIO/WHT
LED Driv
er
To DALI
Controller
DALI/Prog
DALI/Prog
B
DALI controller wiring diagram
A
0-10V dimmer wiring diagram
Optional Installation: 0-10 Volt Dimming or DALI Lighting Controller
4
Replace cover using at least one star washer under
countersunk screwhead.
Star washer
Do not