background image

GE Healthcare

Technical
Publications

Direction 5401576-100
Rev. 1

LOGIQ C Series

Quick Guide

Copyright 2010 By General Electric Co.

Operating Documentation

Содержание LOGIQ C Series

Страница 1: ...GE Healthcare Technical Publications Direction 5401576 100 Rev 1 LOGIQ C Series Quick Guide Copyright 2010 By General Electric Co Operating Documentation ...

Страница 2: ...o KG Beethovenstrabe 239 Postfach 11 05 60 D 42655 Solingen Germany Regulatory Requirement LOGIQ C Series complies with regulatory requirements of the following European Directive 93 42 EEC concerning medical devices Manufacturer GE Medical Systems China Co Ltd No 19 Changjiang Road Wuxi National Hi Tech Development Zone Jiangsu P R China 214028 Tel 86 510 85225888 Fax 86 510 85226688 ...

Страница 3: ...ev 1 1 52 Rev 1 Please verify that you are using the latest revision of this document Information pertaining to this document is maintained on MyWorkshop ePDM GE Healthcare electronic Product Data Management If you need to know the latest revision contact your distributor local GE Sales Representative or in the USA call the GE Ultrasound Clinical Answer Center at 1 800 682 5327 or 262 524 5698 ...

Страница 4: ...isplay th paitent screen 7 Mode Keys B Mode M Mode Press these key to activate the mode 8 Gain Auto Key Rotate the key to adjust the Gain Press the key to activate deactivate auto optimization 9 Zoom Key magnify a zoom region of interest ROI 10 Ellipse Keys activates the area ellipse measurement function 11 Depth Key controls the distance over the images 12 Reverse Print Store Key Reverse key can ...

Страница 5: ... key to display th paitent screen 26 Mode Keys B Mode M Mode Pulsed Wave Doppler PW Modes 27 Gain Auto Key Rotate the key to adjust the Gain Press the key to activate deactivate auto optimization 28 Zoom Key magnify a zoom region of interest ROI 29 Ellipse Keys activates the area ellipse measurement function 30 Depth Key controls the distance over the images 31 Reverse Print Store Key Reverse key ...

Страница 6: ...ent screen 45 Mode Keys B Mode M Mode Pulsed Wave Doppler PW Modes and Color Flow CF Mode Press these key to activate the mode 46 Gain Auto Key Rotate the key to adjust the Gain Press the key to activate deactivate auto optimization 47 Zoom Key magnify a zoom region of interest ROI 48 Ellipse Keys activates the area ellipse measurement function 49 Depth Key controls the distance over the images 50...

Страница 7: ...p Enter Online Help User Manual F2 Arrow Annotation Arrow F3 Eject Eject media F4 Spooler Activates DICOM Job Spooler screen F5 Activate Sub Menu F6 F12 Programmable How to Program your programmable keys Utility Admin Function Key then use the drop down menu Choices for program Keys WorkSheet 3D LOGIQ View ECG On Off Only for LOGIC5 C5PRO Set Home Only for LOGIQC5 C5PRO C3 C3PRO Text Overlay Grab ...

Страница 8: ... Preview 6 Gray Color Bar 7 Cine Gauge 8 Measurement Summary Window 9 Image 10 Measurement not shown 11 Measurement Results Window 12 Probe Identifier Exam Study 13 Imaging Parameters by Mode current mode highlighted 14 Focal Zone 15 TGC not shown on the image 16 Body Pattern 17 Depth Scale 18 Top Sub Menu 19 Caps Lock On or Off 20 Start Menu Icon 21 Card iconTrackball Functionality Status Scroll ...

Страница 9: ...ot disconnect during system use If the system is accidentally unplugged data may be lost Press the Power On Off switch to turn the power on Figure 5 Power on Bottom a Power Switch Location LEDs 1 When connect the system to the electrical supply the LED turns amber Figure 6 Power LED 2 After pressing the Power On Off switch the system power is on and the LED turns Green The Probe Key LED is lit Fig...

Страница 10: ... Disconnect the probes Clean or disinfect all probes as necessary Store them in their shipping cases to avoid damage Starting an Exam You need to select a pre configured dataflow that sets up the ultrasound system to work according to the services associated to the dataflow 1 Select your Operator Login and type in your Password Figure 9 Operator Login Window 2 Press OK 3 Fill in the New Patient me...

Страница 11: ...or to the actual exam being performed Details displays exam details and additional patient information EZBackup EZMove 3 One step method to backup move and delete patient images to an external media Dataflow 4 Selects this exam s dataflow preference Exit 5 Exits the Patient Menu and returns to scanning Patient Information 6 Patient ID Name Birthdate Age and Sex Category Selection and Exam Informat...

Страница 12: ...le image colorization To deactivate reselect a Gray Map Gray Map Determines how the echo intensity levels received are presented as shades of gray Rotation Up Down Rotates the image by selecting the value from the Softkey Frequency Multi Frequency mode lets you downshift to the probe s next lower frequency or shift up to a higher frequency Line density Optimizes B Mode frame rate or spatial resolu...

Страница 13: ...ffects the amount of gray scale information displayed If you increase the gain you may want to decrease the dynamic range Edge Enhance Better delineates the amount of border crispness Frame Average Smooths the image by averaging frames Affects the amount of speckle reduction Virtual Apex Only for LOGIQ C3 C3PRO C5 C5PRO On Sector probes Virtual Apex provides a larger field of view in the far field...

Страница 14: ...tion has been made the color bar displays the resultant map Packet Size Controls the number of samples gathered for a single color flow vector Controls in Common with B Mode For more information on Focal Zone Power Output Frequency Frame Average Dynamic Range Gray Map and Colorize refer to the B M Mode Image Optimize section in this Quick Guide Scanning Hints Line Density Trades frame rate for sen...

Страница 15: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 10 Color Flow Doppler Image Optimize continued Figure 12 CFM Top Sub Menu Controls Figure 13 PWD Top Sub Menu Controls ...

Страница 16: ...n the ellipse and to size the measured axes move the calipers move the Trackball 7 To increase the size adjust the Ellipse control in a clockwise direction To decrease the size adjust the Ellipse control in a counterclockwise direction 8 To toggle between active calipers press Measure 9 To complete the measurement press Set The system displays the circumference and area in the measurement results ...

Страница 17: ...cal dotted line displays 2 To position the caliper at the desired measurement point move the Trackball 3 To complete the measurement press Set The system displays the velocity measurement in the measurement results window PI RI S D Ratio D S Ratio or A B Ratio Only for LOGIQ C3 C3PRO C5 C5PRO Select PI RI S D Ratio A B Ratio or D S Ratio from the Doppler Primary and secondary menu Perform velocity...

Страница 18: ...cally Swich the probe Swich probe between the two probe through pressing Probe bottom NOTE Swiching the probe frequently will cause probe can not be supported warning message Deactivating the probe When deactivating the probe the probe is automatically placed in standby mode 1 Ensure the LOGIQ C Series is in freeze mode If necessary press the Freeze key 2 Gently wipe the excess gel from the face o...

Страница 19: ... RS 3 8C RC 7 5L RC 7L RC 3S RC Abdomen 0 X X 0 Small Parts X X X X Obstetrics X X X X Gynecology X X X Pediatrics X X X 0 0 Neonatal 0 0 0 Urology X X Cardiac X X X Endocavity Transcranial 0 X Intraoperative 0 0 0 Vascular 0 0 0 X X Biopsy X X X X X X X X Main Application O Accessory Application NOTE 3S RC is only available for LOGIQ C3 C3PRO C5 C5PRO ...

Страница 20: ... 2 LOGIQ C5 C5 PRO Probe Features Probe Feature E7C RC E6C RS 6 5C RS 4C RS 3 8C RC 7 5L RC 7L RC 3S RC LOGIQ View X X X X X X X X Virtual Convex X X Virtual Apex X Easy 3D X X X X X X X X Tru Access X X X X X X X X ACO X X X X X X X X NOTE 3S RC is only available for LOGIQ C3 C3PRO C5 C5PRO ...

Страница 21: ...esignation Center Image Frequency MHz Doppler Frequency MHz Normal Penetration E7C RC 6 5 10 5 0 4 0 E6C RC 6 5 10 5 0 4 0 6 5C RC 6 5 10 5 0 4 0 4C RC 3 75 10 3 3 2 5 3 8C RC 3 75 10 3 3 2 5 7 5L RC 7 5 10 4 4 4 0 7L RC 7 5 10 4 4 4 0 3S RC 2 0 10 2 0 1 5 NOTE 3S RC is only available for LOGIQ C3 C3PRO C5 C5PRO ...

Страница 22: ...ly marketed sterile pyrogen free probe sheath is REQUIRED Probes for neuro surgical use must not be sterilized with liquid chemical sterilants because of the possibility of neuro toxic residues remaining on the probe Biological Hazard A defective probe or excessive force can cause patient injury or probe damage Observe depth markings and do not apply excessive force when inserting or manipulating ...

Страница 23: ... recommended time Probes for neuro surgical intra operative use must NOT be sterilized with liquid chemical sterilants because of the possibility of neuro toxic residues remaining on the probe Neurological procedures must be done with the use of legally marketed sterile pyrogen free probe sheaths 3 After removing from the germicide rinse the probe following the germicide manufacturer s rinsing ins...

Страница 24: ...side of the screen Click Save As Select the Removable disk drive Select File Type DICOM JPG or AVI Provide File Name and press Save Before pulling out the memory stick the device should be stopped by clicking on the Eject Hardware Icon see following figure selecting the device and pressing Stop Figure 14 USB Memory Stick Icon Connectivity Connectivity on the LOGIQ C Series is based on the Dataflow...

Страница 25: ... button Figure 17 Connectivity Device Preset Menu Services better known as Destinations 1 Select the Server from the pull down menu 2 Press Add 3 Select all the services for this device from the pull down menu to the right 4 Press Add 5 At the bottom of the menu fill in the appropriate criteria for this service Repeat this step for each selected service for this device For example a In the Service...

Страница 26: ...nt and press Add Change its name to Jdicom Print For AE title enter Jdicom_Printer and for port number enter 7104 Figure 18 Connectivity Services Preset Menu Verify a Service Jdicom Image Storage Select the service press verify button Buttons You can assign print buttons to a device or to a dataflow 1 Select Dicom Image Storage add to Printflow view 2 Delete other printflow Save the change NOTE Yo...

Страница 27: ... for example 1 Name the Dataflow select from pull down menu or add a new dataflow 2 Configure the flow in the Dataflow section of the screen Select the service from the pull down menu and press Add Figure 20 Dataflow Preset Menu DICOM Status To check the status of all DICOM jobs or redirect DICOM jobs press F4 to open the spooler Figure 21 DICOM Status Window ...

Страница 28: ... Softkey to move to the beginning of the CINE Loop Adjust the Start Frame Softkey rightward to move forward through the CINE Loop Adjust the Softkey leftward to move backward through the CINE Loop Press the End Frame Softkey to move to the end of the CINE Loop Adjust the End Frame Softkey rightward to move forward through the CINE Loop Adjust the Softkey leftward to move backward through the CINE ...

Страница 29: ...interest is a tangible anatomical object that you can see and manipulate easily using the Trackball and Set control panel keys Practice positioning the pointer at different places within the 3D volume of interest Highlight different colors press Set to select this volume for manipulation Use the hand to move the 3D volume Adjusting the 3D Volume of Interest You can colorize the 3D volume of intere...

Страница 30: ...lity tab select Service tab in Utility window netscape will show GEMS Service Home Page Select Operator in option of User Level enter correct password uls then press Okay Figure 22 Service Login Window 2 Now user can enter Global Service User interface Choose Diagnostics and then we enter LOGIQ C Series Diagnostics menu Figure 23 Service Screen ...

Страница 31: ...ecifically Maintaining an optimum system environment Using this Manual Notes to emphasize or clarify a point DANGER Indicates that a specific hazard is known to exist which through inappropriate conditions or actions will cause Severe or fatal personal injury Substantial property damage WARNING Indicates that a specific hazard is known to exist which through inappropriate conditions or actions may...

Страница 32: ...7000 No 0659 Electrical Hazard Electrical micro shock to patient e g ventricular Probes ECG if applicable Connections to back panel Acoustic Output Hazard Patient injury or tissue damage from ultrasound radiation ALARA the use of power output following the as low as reasonably achievable principle Explosion Hazard Risk of explosion if used in the presence of flammable anesthetics Flammable anesthe...

Страница 33: ...c information Equipment malfunction or incorrect settings can result in measurement errors or failure to detect details within the image The equipment user must become thoroughly familiar with the equipment operation in order to optimize its performance and recognize possible malfunctions Applications training is available through the local GE representative Added confidence in the equipment opera...

Страница 34: ...lectrical Hazard A damaged probe can also increase the risk of electric shock if conductive solutions come in contact with internal live parts Inspect probes often for cracks or openings in the housing and holes in and around the acoustic lens or other damage that could allow liquid entry Become familiar with the probe s use and care precautions outlined in Probes and Biopsy CAUTION Ultrasound tra...

Страница 35: ...ll peripherals and accessories must be securely connected to the LOGIQ C Series DANGER The concerns listed below can seriously affect the safety of equipment and personnel during a diagnostic ultrasound examination Explosion Hazard Risk of explosion if used in the presence of flammable anesthetics Electrical Hazard To avoid injury Do not remove protective covers No user serviceable parts are insid...

Страница 36: ...r possible Follow sterile procedures when appropriate Thoroughly clean probes and reusable accessories after each patient examination and disinfect or sterilize as needed Refer to Probes and Biopsy for probe use and care instructions Follow all infection control policies established by your office department or institution as they apply to personnel and equipment CAUTION Contact with natural rubbe...

Страница 37: ...or protection IP Code IPX1 IPX1 FSU 2001 Indicates the degree of protection provided by the enclosure per IEC60 529 IPX1 cannot be used in operating room environment IPX8 can be used in operating room environment Bottom of Foot Switch Type BF Applied Part man in the box symbol is in accordance with IEC 878 02 03 Beside the probe connector General Warning Various CAUTION Dangerous voltage the light...

Страница 38: ...006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products The number in the symbol is the Environment friendly Use Period EFUP which indicates the period during which the toxic or hazardous substances or elements contained in electronic information products will not leak or mutate under normal operating conditions so that the use of such electron...

Страница 39: ...lipping down the LCD monitor On the back of LCD Use the rear handle for horizontal movement only On the back of LCD Consult accompanying documents is intended to alert the user to refer to the operator manual or other instructions when complete information cannot be provided on the label Various Table 6 Label Icons Label Icon Purpose Meaning Location ...

Страница 40: ...ly on BASIC INSULATION only but includes an protective earth ground This additional safety precaution prevents exposed metal parts from becoming LIVE in the event of an insulation failure 2 Class Il EQUIPMENT EQUIPMENT in which protection against electric shock does not rely on BASIC INSULATION only but in which additional safety precautions such as DOUBLE INSULATION or REINFORCED INSULATION are p...

Страница 41: ...CF APPLIED PART providing a degree of protection higher than that for Type BF Applied Part against electric shock particularly regarding allowable LEAKAGE CURRENTS Table 8 Type CF Equipment Normal Mode Single fault condition Patient leakage current Less than 10 microA Less than 50 microA ...

Страница 42: ...ect the problem by one or more of the following measure s reorient or relocate the affected device s increase the separation between the equipment and the affected device power the equipment from a source different from that of the affected device consult the point of purchase or service representative for further suggestions NOTE The manufacturer is not responsible for any interference caused by ...

Страница 43: ...uct In case of issues related to EMC please call your service personnel The manufacturer is not responsible for any interference caused by using other than recommended interconnect cables or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the users authority to operate the equipment CAUTION Do not use devices which intentionally transmit ...

Страница 44: ...he ultrasound system or using an RF shielded examination room may be necessary 1 Use either power supply cords provided by GE Medical Systems or ones designated by GE Medical Systems Products equipped with a power source plug should be plugged into the fixed power socket which has the protective grounding conductor Never use any adaptor or converter to connect with a power source plug i e three pr...

Страница 45: ...oor EMC performance of the product 2 Notice against User Modification The user should never modify this product User modifications may cause degradation in EMC performance Modification of the product includes changes in a Cables length material wiring etc b System installation layout c System configuration components d Securing system parts cover open close cover screwing 3 Operate the system with...

Страница 46: ...e system conform to the requirements of IEC EN 60601 1 1 General precautions for installing an alternate device in patient environment would include 1 The added device must have appropriate safety standard conformance and CE Marking 2 There must be adequate stability of the combination between LOGIQ C Series and Peripherals 3 Risk and leakage current of the combination must comply with IEC EN 6060...

Страница 47: ...e Electromagnetic Environment CISPR 11 RF Emissions Group 1 Class A This system uses RF energy only for its internal function Therefore RF emissions are very low and are not likely to cause any interference in nearby electronic equipment It is suitable for use in all establishments including Class B other than Class A domestic establishments and those directly connected to the public low voltage p...

Страница 48: ... be at levels characteristic of a typical location in a typical commercial and or hospital environment Separation distance to radio communication equipment must be maintained according to the method below Interference may occur in the vicinity of equipment marked with the symbol IEC 61000 4 4 Electrical fast transient burst 2 kV for mains 1 kV for SIP SOP 2 kV for mains 1 kV for SIP SOP IEC 61000 ...

Страница 49: ... LOGIQ C2 C2PRO 3 Right side Probe holder 5 Inside Printer Box 1 USB port Only for B W Printer 1 Front panel Probe Port Left side 1 USB port Peripheral devices B W Printer Officejet Printer Memory Stick Footswitch USB HDD ECG Color Printer Rear panel 2 USB Ports Peripheral devices B W Printer Officejet Printer Memory Stick Footswitch USB HDD ECG Color Printer 1 VGA Port 1 S Video Port 1 Composite ...

Страница 50: ...es on page 41 for more information CAUTION Unapproved devices such as unsupported printers VCRs etc should not be used in the patient environment If devices are connected without the approval of GE the warranty will be INVALID Any device connected to the LOGIQ C Series must conform to one or more of the requirements listed below 1 IEC standard or equivalent standards appropriate to devices 2 The d...

Страница 51: ...mperature increase in soft tissue Bone Thermal Index TIB Used when bone is near the focus of the image as in the third trimester OB examination it provides an estimate of potential temperature increase in the bone or adjacent soft tissue Cranial Bone Thermal Index TIC Used when bone is near the skin surface as in transcranial examination it provides an estimate of potential temperature increase in...

Страница 52: ...ry and probe selected It takes effect when the system is powered on or New Patient is selected HINTS Increase the Acoustic Output only after attempting image optimization with controls that have no effect on Acoustic Output such as Gain and TGC WARNING Be sure to have read and understood control explanations for each Mode used before attempting to adjust the Acoustic Output control or any control ...

Страница 53: ...e devices near this equipment could cause this equipment to perform outside the published specifications Keep power to these devices turned off when near this equipment 4 The equipment weighs approximately 70 kg 154 32 lbs To avoid possible injury and equipment damage when transporting from one area of use to another Be sure the pathway is clear Limit movement to a slow careful walk Use two or mor...

Страница 54: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 49 Safety Console Labels continued Figure 26 LOGIQ C2 C2PRO Rating Plate Label Location For 100V 120V AC ...

Страница 55: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 50 Console Labels continued Figure 27 LOGIQ C2 C2PRO Rating Plate Label Location For 220V 240V AC ...

Страница 56: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 51 Safety Console Labels continued Figure 28 LOGIQ C2 C2PRO Rating Plate Label Location China only ...

Страница 57: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 52 Console Labels continued Figure 29 LOGIQ C2 C2PRO Rating Plate Label Location CKD Version India only ...

Страница 58: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 53 Safety Console Labels continued Figure30 LOGIQ C3 C3PRO Rating Plate Label Location For 100V 120V AC ...

Страница 59: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 54 Console Labels continued Figure 31 LOGIQ C3 C3PRO Rating Plate Label Location For 220V 240V AC ...

Страница 60: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 55 Safety Console Labels continued Figure 32 LOGIQ C3 C3PRO Rating Plate Label Location China only ...

Страница 61: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 56 Console Labels continued Figure 33 LOGIQ C3 C3PRO Rating Plate Label Location Korea only ...

Страница 62: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 57 Safety Console Labels continued Figure 34 LOGIQ C3 C3PRO Rating Plate Label Location CKD Version India only ...

Страница 63: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 58 Console Labels continued Figure 39 LOGIQ C5 C5PRO Rating Plate Label Location For 100V 120V AC ...

Страница 64: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 59 Safety Console Labels continued Figure 40 LOGIQ C5 C5PRO Rating Plate Label Location For 220V 240V AC ...

Страница 65: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 60 Console Labels continued Figure 41 LOGIQ C5 C5PRO Rating Plate Label Location China only ...

Страница 66: ...LOGIQ C Series Quick Guide Direction 5401576 100 Rev 1 61 Safety Console Labels continued Figure 42 LOGIQ C5 C5PRO Rating Plate Label Location Korea only ...

Страница 67: ...Mailing Address Fax To Fax Number Attention Coakley Tech 414 389 9130 Norm Keene Publication Language Direction Number Publication Language Direction Number Basic User Manual please select one language English 5268596 100 Quick Guide English 5401576 100 French 5268596 101 Basic Service Manual English 5273008 100 Spanish 5268596 106 Portuguese 5268596 127 Italian 5268596 111 German 5268596 108 Chin...