Installation Manual 

KTD-135 Series 

 

M

AKING 

C

ABLE 

C

ONNECTIONS

 

1) 

Prepare the power cable by cutting off the plug with a pair of wire 
cutters and stripping the wires approximately ¼ inch (6.35 mm). 
See Figure 2. 

 

 

Figure 2.  Preparing the power cable 

 

1037275B / April 2004 

Содержание KTD-135 Series

Страница 1: ...KTD 135 Series Door Receivers ...

Страница 2: ... CAUTION Complete all installation steps before supplying power to the unit MOUNTING THE UNIT 1 Choose a mounting location for the unit 2 Using the unit s mounting flanges as a template mark the location of the mounting holes See Figure 1 Figure 1 Mounting flanges 3 Drill and prepare the mounting holes for the type of surface and fasteners not provided being used 4 Mount the unit with fasteners ap...

Страница 3: ...Series MAKING CABLE CONNECTIONS 1 Prepare the power cable by cutting off the plug with a pair of wire cutters and stripping the wires approximately inch 6 35 mm See Figure 2 Figure 2 Preparing the power cable 1037275B April 2004 3 ...

Страница 4: ... strip as shown in Figure 3 Observe polarity 9 VAC power input Call bus to keypad RS422 in Call bus from other receivers RS422 out Relay contact Audio bus to from keypad Speaker Audio bus to from other receivers Call button Connect audio shields Figure 3 Cable connections 4 1037275B April 2004 ...

Страница 5: ... DIP SWITCH 1 Remove the unit s cover by removing the two cover screws See Figure 4 Figure 4 Removing the cover 2 Locate the unit s DIP switch See Figure 5 Site select switches Termination switches Figure 5 DIP switch location 1037275B April 2004 5 ...

Страница 6: ...and turn the DIP switch positions that correspond to those values to ON Table 1 DIP switch values Switch Value 1 1 2 2 3 4 4 8 5 16 6 32 7 64 4 If the RS422 control cable does not loop out of the receiver to another unit turn the termination switches in Figure 5 to ON JUMPER SETTINGS The unit s configuration jumper see Figure 6 is preset at the factory to set terminals 15 and 16 as a normally open...

Страница 7: ... N O dry contact Terminals 15 and 16 DC output terminal 15 DC terminal 16 common Figure 6 Jumper settings for terminals 15 and 16 PREPARING THE UNIT FOR USE 1 Make sure that all cable connections are secure 2 Supply power to the unit 1037275B April 2004 7 ...

Страница 8: ......

Отзывы: