GE JVX5300 Скачать руководство пользователя страница 9

49-80783-3

9

Installation 
Instructions

INST

ALLA

TION INSTRUCTIONS

BEFORE YOU BEGIN

Read these instructions completely and 
carefully.

• 

 

IMPORTANT

 — 

Save these 

instructions for local inspector’s use.

 

 

IMPORTANT

 —

 Observe all governing 

codes and ordinances.

   Note to Installer 

– Be sure to leave these 

instructions with the Consumer.

•  

Note to Consumer 

– Keep these instructions for 

future reference.

• 

 Skill level 

– Installation of this vent hood requires 

basic mechanical and electrical skills.

•  

Proper installation is the responsibility of the 
installer. 

•  

Product failure due to improper installation is not 
covered under the Warranty.

FOR YOUR SAFETY

WARNING

 Before beginning the installation, 

switch power off at service panel and lock the 
service disconnecting means to prevent power from 
being switched on accidentally. When the service 
disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, 
to the service panel.

CAUTION

 To reduce risk of fire and to 

properly exhaust air, be sure to duct air outside. 
Do not vent exhaust air into spaces within walls or 
ceilings or into attics, crawl spaces or garages.

WARNING

 Disconnect all electrical power 

at the main circuit breaker or fuse box before 
installing.

Under the Cabinet (UTC) Hoods

JVX3240, JVX3300, JVX5300, JVX5360, JVX5305, 
JVX5365, PVX7300, PVX7360

WARNING

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:

A.  Installation work and electrical wiring must be 

done by qualified person(s) in accordance with 
all applicable codes and standards, including 
fire-rated construction.

B.  Sufficient air is needed for proper combustion 

and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent 
back drafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards 
such as those published by the National Fire 
Protection Association (NFPA), the American 
Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE) and the local 
code authorities. 

C.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 
utilities.

D.  Ducted fans must always be vented to the 

outdoors.

WARNING

 

TO REDUCE THE RISK OF FIRE, 

USE ONLY METAL DUCT WORK.

 

  “If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) 

or visit our website at: GEAppliances.com”

Содержание JVX5300

Страница 1: ...pliances com RANGE HOODS 49 80783 3 08 16 GEA SAFETY INFORMATION 3 USING THE HOOD Controls 5 Chef Connect 6 CARE AND CLEANING Filters 7 Surfaces 8 Lights 8 INSTALLATION INSTRUCTIONS 9 TROUBLESHOOTING...

Страница 2: ...nto every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need...

Страница 3: ...cooking at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flanb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D...

Страница 4: ...with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to a provide reasonable protection against harmful interference in a residential installatio...

Страница 5: ...s to activate auto off after 15 minutes 4 Fan Settings Buttons Speed control for fan Press the button Lo for LOW speed Med for MEDIUM speed and Hi for HIGH speed Hold down the Hi button for 3 seconds...

Страница 6: ...hood press and hold the Light pad for 3 seconds The backlight for the Lo Med Hi Light will flash in that sequence until the hood is paired with the range or other device If the pairing is successful...

Страница 7: ...ilter that helps remove smoke and odors NOTE DO NOT rinse or put charcoal filter in an automatic dishwasher The charcoal filter cannot be cleaned It must be replaced It is recommended that the charcoa...

Страница 8: ...suitable for painted surfaces About one tablespoon of ammonia may be added to the water Use a clean hot damp cloth to remove soap Dry with a dry clean cloth NOTE When cleaning take care not to come i...

Страница 9: ...in walls or ceilings or into attics crawl spaces or garages WARNING Disconnect all electrical power at the main circuit breaker or fuse box before installing Under the Cabinet UTC Hoods JVX3240 JVX330...

Страница 10: ...ct Do not use less than a 7 diameter duct Duct length The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest stra...

Страница 11: ...This hood must be installed onto a cabinet It can be vented to the outdoors or it can be installed for recirculating operation Bottom edge of cabinet needs to be 30 or more from the cooking surface 24...

Страница 12: ...e risk of fire and to properly exhaust air be sure to duct the air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PARTS SUPPLIED FOR INSTAL...

Страница 13: ...NGE HOOD COMPONENTS A Hood Body B DPSHU XFW RQQHFWRU C Mounting Bracket D Screws 4 E Screws 4 F Screws 6 HARDWARE COMPONENTS D E F C C B A D D E F E 12 X X Distance from hood to cooktop varies dependi...

Страница 14: ...qualified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVANCE PLANNING Vented Install Planning This hood is designed to be vented vertically us...

Страница 15: ...e needed for cabinets with a recessed bottom Skip to step B A To install the mounting bracket Drive E screws in partway into mounting bracket The bracket labeled R will be used on the right side of th...

Страница 16: ...und Use the diagram as a template and mark the locations on the cabinet for ductwork and electrical wiring C Outside rear exhaust Horizontal duct 3 1 4 x 10 Rectangular Use the diagram as a template a...

Страница 17: ...OTE For an ENERGY STAR model unit must be vented mode to be considered ENERGY STAR certified 7 ATTACH DAMPER DUCT CONNECTOR Attach damper duct connector over knockout opening with two or four D screws...

Страница 18: ...e deflector part 10 MOUNT THE UTC Place the hood onto the partially installed screws using the keyholes and slide the hood back into position 9 FEED IN WIRES Lift the hood into position and feed the h...

Страница 19: ...ith a wire nut C Attach the black lead of the power supply to the black lead of the range hood B with a wire nut C Connect the green D ground wire under the green grounding screw 2 Replace the junctio...

Страница 20: ...is making loud or abnormal airflow noise Obstructions in duct work Make sure nothing is blocking the vent Make sure your wall or roof cap has a blade or door Damper blade on wall or roof cap may not b...

Страница 21: ...TY GE Appliances Vented Range Hood Warranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the i...

Страница 22: ...er to the Consumer Support page for phone numbers and website information The following products and more are available Accessories Parts Charcoal Filter Remote Control Replacement Lights 15 Cabinet F...

Страница 23: ...49 80783 3 23 Notes...

Страница 24: ...in effect You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com ge service and support shop for extended service plans h...

Отзывы: