background image

Listed by 

Underwriters 

Laboratories

JVM6175SK/EK 

GE Appliances 1.7 cu. ft. Over-the-Range Sensor Microwave Oven

Specification Created 2/16

Filler Panel Kit JX36CSS and 

JX36CES
When replacing a  36" range  

hood, this kit fills in the additional 

width to provide a custom built-in  

appearance. For installation  

between  cabinets only;  

not for end-of-cabinet  

installation. Each kit   

contains two 3"-wide  

filler panels. 

Filter Kit JX81J–

Recirculating 

Charcoal Filter Kit 

To be used when 

the microwave oven 

cannot be vented  

to the outside.

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

HOOD EXHAUST DUCT:

 Outside ventilation requires a HOOD 

EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION:

 The hood exhaust has been designed to mate 

with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a 

rectangular-to-round transition adaptor must be used. Do not use less than a 
6" diameter duct

REAR EXHAUST:

 If a rear or horizontal exhaust is to be used, care should be 

taken to align exhaust with space between studs, or wall should be prepared 
at the time it is constructed by leaving enough space between the wall studs to 

accommodate exhaust.

MAXIMUM DUCT LENGTH:

 For satisfactory air movement, the total duct 

length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 
140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS,

 etc., present 

additional resistance to airflow and are equivalent to a section of straight 
duct which is longer than their actual physical size. When calculating the total 
duct length, add the equivalent length of all transitions and adaptors plus the 
lengths of all straight duct sections. The chart below shows the approximate 
feet of equivalent length of some typical ducts.

DUCT

EQUIVALENT FEET 

A.

   Rectangular-To-round 

Transition Adaptor

5 ft.

B.

 Wall Cap

40 ft.

C. 

90° Elbow

10 ft.

D.

 45° Elbow

5 ft.

E.

 90° Elbow

25 ft.

F.

 45° Elbow

5 ft.

G.

 Roof Cap

24 ft.

OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) 

Отзывы: