Door Switches, Continued

P r i m a r y   S w i t c h

A. Closed circuit when the door is closed, 
open circuit when the door is open. 

B. Open circuit when the door is closed, 
closed circuit with door open. 

C. Same function as switch A. 

Thermostats and Thermal Cut Outs

 

Cavity TCO

Bottom TCO

Hood TCO

Magnetron 

TCO

The interlock switches are not adjustable. 

7KHVZLWFKKRXVLQJLV¿[HGRQWKHIURQWRIWKH

cavity with two screws. 

IMPORTANT: Check for microwave leakage 
after replacing or adjusting the door.  

Bottom TCO

The Bottom TCO opens the line voltage to the 

XQLWLQFDVHRIDUDQJHFRRNWRS¿UHGLVDEOLQJ

the oven. It opens at 250 degrees and is   
non-resettable. 

Hood TCO

7KH+RRG7&2ZLOODFWLYDWHWKHH[KDXVWYHQW

blower if the bottom of the unit reaches 158 
degrees. The vent blower will turn off when 
the bottom cools to 104 degrees. It is normal 
for the fan to operate after the oven is turned 
off.

Cavity TCO

The Cavity TCO is a thermal cut out and 
disables oven operation when the top cavity 
duct temperature reaches 230 degrees. This 
provides protection for the microwave in case 

RIDQRYHUKHDWFRQGLWLRQRUIRRG¿UHLQWKH

oven cavity. The cavity TCO is non-resettable. 

Cavity TCO - Replacement

The Cavity TCO is located on the top side 

RIWKHRYHQFDYLW\EHVLGHWKHH[KDXVWGXFW

behind a plastic door. The TCO is tightly held 
to the top of the cavity by a spring clip. It can 
be accessed without removing the unit from 

WKHLQVWDOODWLRQ,IGLI¿FXOWLHVDUHHQFRXQWHUHG

uninstall the oven and remove the outer case.

([KDXVW'XFW

Turn Table Motor 

To Service the Turntable Motor
Disconnect power and remove bottom plate 

VFUHZV5HPRYHERWWRPSODWHDQGGLV

-

connect the turntable motor wire. Remove 

WKHWXUQWDEOHVFUHZVDQGSXOOWKHWXUQWDEOH

motor.

Primary Switch

A

Secondary Switch

C

Monitor Switch

B