ips

Install Downdraft Vent

Place the downdraft vent into the countertop
cutout, against the back side.

Secure the downdraft to the countertop

supplied brackets. See illustration.
Fasten brackets to top screws on the front

side of the vent, secure to cabinet side wall

just below the countertop. Or,

Fasten one bracket to vent side and secure to

cabinet back wall. 

Install two brackets on the bottom of the 

vent.  Attach brackets to slide screws on 

the vent and to the floor using wood screws

(not supplied). 

When installing in a tile countertop surface, it may be
necessary to apply a locally approved caulking to cover 
any gaps.

Optional method secure
to cabinet side with top
screw on case

Or use second screw

Secure the lower brackets 

to blower housing

Preferred method
Secure the upper
brackets with screws
located on the side of
case and attach to back
of cabinet

Install the Ductwork

Use minimum 26

gauge galvanized or 24 gauge

aluminum duct 3

1

4

x 10

″ 

or 6

round. PVC duct

should be used if installing under a poured
concrete slab.

DO NOT USE

flexible ducting.

Always use appropriate roof or wall cap with

damper. Laundry type wall caps should never

be used.

Use the straightest duct run possible.

For satisfactory performance the duct run

should not exceed 150 ft. or its equivalent

length when bends or various fittings are used.

Refer to the table of equivalent lengths to

calculate your installation.

Install ductwork so the piece of duct nearest the

downdraft unit slots 

INTO

the next piece of the

duct. Secure the joints with self-tapping screws

and apply duct tape around the joints to ensure

an airtight seal.

15

Air

Flow

Screw

Duct tape over
seam and screw

Содержание JVB67

Страница 1: ...7 8 4 3 1 2 5 6 7 8 4 3 1 2 5 6 7 8 4 3 1 2 5 6 7 8 4 3 1 2 5 6 7 8 4 3 1 2 UNIT ON Part No 164D3333P161 Pub No 49 8931 D 959 0278 000 11 98 CG JVB37 JVB67 Owner s Manual Installation Instructions Vent Systems Downdraft ...

Страница 2: ...your purchase and hope you will continue to rely on us wheneveryouneedqualityappliancesforyourhome Inside you will find many helpful hints on how to use and maintain your vent properly Just a little preventive care on your part can save you a great deal of time and money over the life of your vent You ll find many answers to common problems in the Before You Call For Service section If you review ...

Страница 3: ...t air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code author...

Страница 4: ...TMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back...

Страница 5: ...nient operation set the blower to the speed you use most often The blower will come on to this speed whenever the unit is raised Remote RAISE LOWER switch 36 models only 36 models have a remote RAISE LOWER switch It operates in the same manner as the switch located on the vent RAISE LOWER switch location may vary Using the Cooktop Caution Be careful when raising or lowering the downdraft Be sure p...

Страница 6: ...ir movement of this downdraft system can increase the cooking times for some foods It may take longer to reach high cooking temperatures if the downdraft is turned to high right away Adjust the fan speed for best cooking results For best results when heating oil for deep frying or when boiling water use the front surface units or wait until the water is boiling or the oil is at frying temperatures...

Страница 7: ...ture use NOTE This appliance must be properly grounded WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified persons s in accordance with all applicable codes and standards including fire rated construction B Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire...

Страница 8: ...placement and necessary clearances when planning installation Refer to your specific cooktop installation instruction for other appropriate clearances Avoid placing cabinetry directly above the cooking surface when possible If cabinetry is used above the cooking surface Installation must conform with local codes Use cabinets no more than 13 deep Maintain 30 minimum clearance between cooktop and un...

Страница 9: ...e placed on the back wall of the cabinet because it may interfere with the downdraft plenum Install a standard electrical outlet within reach of the vents two foot long power cord The vent and a gas cooktop combination can operate from the same 120 volt standard duplex outlet Electric cooktops must operate from a separate 240 volt junction box Tools and Materials Required Large flat blade screwdri...

Страница 10: ... a cutting guide Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular to sides Planning Installation 30 Electric Gas Cooktops with Downdraft Vents Preparing Cutout Cooktop Surface Surface Depth Minimum Setback Combined Cutout Combined Cutout Model No Overall Width Overall Depth with Downdraft Cutout to Front Edge Width Depth JP326 30 1 4 21 1 4 23 3 8 2 1 2...

Страница 11: ...w as a cutting guide Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular to sides Planning Installation 36 Electric Gas Cooktops with Downdraft Vents Preparing Cutout Cooktop Surface Surface Depth Minimum Setback Combined Cutout Combined Cutout Model No Overall Width Overall Depth with Downdraft Cutout to Front Edge Width Depth JP626 35 1 2 21 23 2 1 2 33 ...

Страница 12: ...llustration for the cooktop model you are installing with this downdraft vent Draw lines on the countertop to follow as a cutting guide Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular to sides Planning Installation 30 Electric Gas Cooktops with Downdraft Vents Preparing Cutout Cooktop Surface Cooktop Surface Surface Depth Cooktop Cutout Vent Cutout Mod...

Страница 13: ...xible ducting If flexible metal ducting is used all equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible DO NOT use flexible plastic ducting Add equivalent lengths for all duct pieces and transitions used to ensure that the duct run does not exceed the maximum 150 Duct Equivalent Duct Equivalent Duct Equivalent...

Страница 14: ...re dropping into the countertop opening Flatten the shipping box to use as a pad Lay the vent on its back onto the pad To change to a left or right discharge Remove 4 nuts holding the blower to the mounting plate See illustration One nut is just inside the blower discharge Remove and turn the blower to the right or left Reinstall the 4 nuts To locate the ductwork holes in the cabinet floor or side...

Страница 15: ...n case Or use second screw Secure the lower brackets to blower housing Preferred method Secure the upper brackets with screws located on the side of case and attach to back of cabinet Install the Ductwork Use minimum 26 gauge galvanized or 24 gauge aluminum duct 31 4 x 10 or 6 round PVC duct should be used if installing under a poured concrete slab DO NOT USE flexible ducting Always use appropriat...

Страница 16: ... snap into position Secure wire box to vent with screws provided Center the mounting bracket over the hole and mark pilot holes Remove and drill pilot holes Mount the metal switch bracket with screws not provided choose screws for your type of countertop or use locally approved adhesive Tie a knot in the lead as close to the switch as possible This will prevent the lead from being pulled away from...

Страница 17: ...or below the cabinet floor JXBC57 optional outdoor cover accessory for remote installation of blower and motor assembly on an outside wall Installing the Cooktop Align the cooktop with the downdraft and fasten cooktop in place NOTES Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered There should be a gap of 1 16 1 8 ...

Страница 18: ...ervice Problem Possible Causes What To Do Fan does not work The vent is not fully extended Press the RAISE LOWER switch The blower control switch may Slide it to the right be in the OFF position Vent does not rise Vent not plugged into an outlet Plug vent in RAISE LOWER switch did Hold switch down for a couple of seconds to not engage lift motor activate motor Circuit breaker may Check circuit bre...

Страница 19: ...he replaceable filters Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage to personal property caused by possible defects with this appliance What GE Will Not Cover This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA In Alaska the warranty excludes the cost of shipping or...

Страница 20: ...expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since impro...