Venting

This hood must be vented vertically through

upper cabinets or horizontally through an outside

wall. Ductwork is not included.
Improper duct sizing or restrictive roof caps

reduce air moving capacity and will not provide

enough ventilation for an indoor electric grill.
Indoor electric grills produce more smoke than

normal cooking and require at least 410 CFM to

provide adequate ventilation. 
Follow the guidelines for proper duct sizing in the

ducting charts. NOTE: The venting system must

exhaust to the outside.

Cabinet Height

For most efficient operation, the top of the hood should
be approximately 66

(167.6 cm) from the floor.

Tools Required:

• Drill; 1

1

4

wood bit.

• Pliers.

• Flat blade screwdriver. • Pencil, ruler and level.
• Saber saw or keyhole saw.
• Caulking, metal snips, duct tape, ducts (with
elbow and transition, if necessary) and wall cap
or roof caps, as required.

INSTALLATION INSTRUCTIONS

Installing the Range Hood

Determine which direction the vent will be
installed (top or rear).
1. Remove filters and motor/light cover (3 screws).
2. Remove the blower motor by removing the
“packing screw” and the clip on the retainer bar. 
Discard the clip and screw.
Unplug the motor from the junction box.
Snap the blower retainer 
bar toward the rear of
the hood to release the
blower. Remove the
blower.
3. Remove the junction
box cover.
Remove the selected wiring knockout and duct
knockout from the top or rear of the hood. Use a
flat blade screwdriver to cut the tabs.

IMPORTANT: OBSERVE ALL GOVERNING
CODES AND ORDINANCES.
SAVE THESE INSTRUCTIONS FOR THE
LOCAL ELECTRICAL INSPECTOR’S USE.

WARNING: Disconnect power before servicing or cleaning the unit.

Blower Control

Care of Filter

Motor

The speed control can be adjusted
from OFF to high speed. At the
highest setting, the blower exhausts
410 CFM. It takes about 15 seconds
for the blower to reach high speed..
For most effective removal of smoke
and odors, turn the fan on at the
beginning of cooking and allow it to
run until smoke and odors are
removed from the room.

For greatest efficiency the aluminum
filter should be cleaned periodically.
To remove the filter, pull the tab to
the side and then down. Soak it in hot
water and detergent. Rinse and dry
thoroughly before replacing.

Lights

Care of Exterior Surfaces

This hood has two lights. Do not use
bulbs larger than 75 watts. There are
two light levels. To change light
bulbs, first remove the filters. It is not
necessary to remove the blower cover.

Use a mild detergent to clean the hood.
DO NOT use abrasive cleansers.

Top Vent
Knockout

Snap 

lock blower

retainer bar

When the control is not set on high
and if the motor seems to be
operating at high speed or if
ventilation seems inadequate, check
the following:
1. Knockouts not removed from hood.
2. Blower installed for vertical

discharge instead of horizontal
discharge or vice versa.

3. Damper blade not opening.
4. Reduced airflow because the duct is

too small or the length is too long.

5. The duct is blocked.
6. Undersized or restrictive wall or

roof cap.

Содержание JV376

Страница 1: ...ll or ceiling do not damage electrical wiring and other hidden utilities F Ducted fans must always be vented to the outdoors G To reduce the risk of fire use only metal ductwork H This unit must be grounded WARNING TO REDUCE THE RISK OFA RANGE TOP GREASE FIRE A Keep fan filters and grease laden surfaces clean B Always turn hood ON when cooking at high heat C Don t leave range unattended when cooki...

Страница 2: ...ar of the hood Use a flat blade screwdriver to cut the tabs IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR S USE WARNING Disconnect power before servicing or cleaning the unit Blower Control Care of Filter Motor The speed control can be adjusted from OFF to high speed At the highest setting the blower exhausts 410 CFM It takes about ...

Страница 3: ...tal screws 8 x 1 4 Check the damper for free operation Open the damper blade to approximately 80 degrees Position the blower for vertical discharge The air flow arrow on the blower should point up towards the vent opening When the blower is in position snap the blower retainer bar toward the front into the indent Reattach the plug into the junction box Blower discharge Air flow arrow This surface ...

Страница 4: ... the product if it is used for other than its intended purpose or used commercially Damage to product caused by accident fire floods or acts of God WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES WHAT IS COVERED FULL ONE YEAR WARRANTY For one year from date of original purchase we will provide free of charge parts and service labor in your home to repair or replace any part of the hood that...