Страница 2: ...es do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will...
Страница 3: ...dance with local building code requirements Visit GEAppliances com for available makeup air solutions C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden u...
Страница 4: ...ou do However the grease filter should be cleaned at least once a month To remove Pull down on the center of the front edge of the filter The filter will then slip out of the retaining tabs on the bac...
Страница 5: ...l filter that helps remove smoke and odors The charcoal filter should be replaced after 6 to 12 months depending on hood usage To remove Pull down on the center of the front edge of the filter The fil...
Страница 6: ...hould not exceed 65 equivalent feet See the WORKSHEET CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH section NOTE It is important that ducting be installed using the most direct route and with as few elbo...
Страница 7: ...nd 9 Ft x Ft 45 elbow 7 Round 28 Ft x Ft wall cap 21 ft w o with damper x Ft damper 7 Round 39 Ft x Ft roof cap 7 Round 1 Ft x Ft to 31 4 x 10 rect transition 7 Round 5 Ft x Ft to 31 4 x 10 rect trans...
Страница 8: ...INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES Hood width may be greater than the width of the range or cooktop but it may not be smaller Ensure the range or cooktop is installed per manufacturer s...
Страница 9: ...7 Round A C B Recirculating non vented ductless D Installation Instructions CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from t...
Страница 10: ...s to be recirculated skip to the next step Remove the baffle from the top of the hood Reinstall the baffle so the short side marked VENTED is visible The long side of the baffle should be inside the h...
Страница 11: ...ivot depending on installation FOR 7 ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Bend up the duct alignment ears in preparation for later attachment of the 7 duct 6 7 Installation Instructions...
Страница 12: ...shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom 95 8 13 8 33 4 1 2 A Outside top exhaust Vertical duct 3 1 4 x 10 Rectangular Use the diagram or the...
Страница 13: ...nt ears Use duct tape to make joints secure and airtight Duct tape 13 Attachment ear tabs 7 round duct SECURE HOOD Slide the hood back against the wall Tighten the mounting screws Be sure the screw he...
Страница 14: ...or restrictive wall or roof cap If the hood seems to make excessive noise Fan may be hitting the filter Turn off the fan and remove the filter Bend the filter down slightly in the center into a dome...